AnyWireASLINK System Products Guide
ASLINKER
B281□B-02U□-CC20
■ Note on use ⇒A separate Address Writer is required to set addresses and other data.
*
For more information, refer to [Various Settings] on page 9.
[Type]
B281SB-02U-CC20
B281XB-02U-CC20
B281PB-02U-CC20
[Notes on Safety]
Precautions that must be observed in order to use this system safely are indicated as shown below.
You must observe these precautions.
A WARNING indicates a potentially hazardous
WARNING
situation which, if not handled correctly, could
result in death or serious injury.
○ System Safety
WARNING
This system is intended for general industrial applications. It does not have functions for supporting applications requiring higher
levels of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes.
○ Always turn off the power in installing or replacing the system.
○ Prolonged continuous ow of a rated load current or higher or a transit current due to load short-circuit, etc., in the hybrid unit including
the output unit and the output circuit may result in smoking or ring. An external safety device such as a fuse must be installed.
○ System power supply
CAUTION
Use a stable, 24V DC power supply. Use of an unstable power supply may cause problems with the system.
○ Separately route high-voltage and power cables
Although the AnyWireASLINK has a high noise margin, install the transmission line and I/O cables away from high-voltage and power
cables.
○ Connectors and terminals
- Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither overloaded nor disconnected.
- Make sure to prevent any metal objects from getting inside the connectors or the terminal blocks.
- Short-circuits caused by metal objects or mis-wiring are likely to damage the device.
○ Do not impose any external loads on the units. Doing so may cause a failure.
○ Do not disconnect or reconnect between the transmission line and slave units when the transmission line is active. A malfunction may occur.
○ Use the AnyWireASLINK within the range of the speci cations and conditions shown below.
[Warranty]
■ Warranty period
The warranty on the delivered Product shall continue to be effective for one (1)
year after the delivery thereof to a location as designated by the original owner.
■ Scope of warranty
Should a defect occur in any part of the Product during the foregoing warranty
period when it is used normally in accordance with the speci cations described
in this Products Guide, the Company shall replace or repair the defect free of
charge, except when it arises as a result of:
[1] Misuse or abuse of the Product by the owner;
[2] Fault caused by other than the delivered Product;
[3] The unauthorized modi cation or repair of the Product by any person other
than the Company's personnel;
[4] Any unusual force of nature, disaster or other cause beyond the Company's
control.
The term "warranty," as used herein, refers to the warranty applicable to the
delivered product alone. The Company shall not be liable for consequential or
incidental damages resulting from any malfunction.
■ Repair at cost
After the expiration of the warranty period, the owner shall be responsible for all
costs and expenses incurred for the troubleshooting and repair of the Product.
Even during the warranty term, the Company shall repair any defects arising
from causes other than within the scope of the warranty as speci ed above, at
the owner's cost.
■ Changes in the product speci cations and the descriptions in the manual
The descriptions in this manual may be subject to change without notice.
NPN input
NPN input/NPN output
NPN output
-B281*B02U*CC20 1/17-
B281SB-02US-CC20
PNP input
B281XB-02US-CC20
PNP input/PNP output
B281PB-02US-CC20
PNP output
A CAUTION indicates a potentially hazardous situation
CAUTION
which, if not handled correctly, may result in personal
injury or property damage.
[About Pictogram *
*
1 The pictogram may not be marked (or stuck) depending on the product.
*
2 AnyWireASLINK device not compatible with Ver. 1.1 (word transmission and
single unit simplified replacement functions)
Some products, not marked with the Ver. 1.1 pictogram, are compatible with
the functions included in Ver. 1.1. Refer to the lot No. and the product guide
for ultimate confirmation.
*
3 For details of Ver. 1.1, refer to the subsequent pages.
]
1
Compatible with
Ver. 1.0*
2
Ver.1.1
LINK
IN
IN
OUT
OUT
ALM
Ver. 1.1*
3

Advertisement

loading
Need help?

Need help?

Do you have a question about the B281-B-02U-CC20 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Anywire B281-B-02U-CC20 Series

  • Page 1 AnyWireASLINK System Products Guide Ver.1.1 ASLINKER LINK B281□B-02U□-CC20 ■ Note on use ⇒A separate Address Writer is required to set addresses and other data. For more information, refer to [Various Settings] on page 9. [Type] B281SB-02U-CC20 NPN input B281SB-02US-CC20 PNP input NPN input/NPN output B281XB-02U-CC20 B281XB-02US-CC20...
  • Page 2 [About AnyWireASLINK Ver. 1.1] New functions have been added to AnyWireASLINK products in May 2019 onward. Also, for the purpose of differentiation of compatible functions, indication of product lot number (lot No.) has been changed. Compatible functions vary depending on lot No. Please understand the following description thoroughly to use each product.
  • Page 3: Master Unit

    [About Single Unit Simplified Replacement] During replacement of a slave unit, this function enables automatic settings of address and parameters of the existing slave unit into a new slave unit. (After replacement of the slave unit, address and parameter setting procedure using the address writer is not required.) ■Step 1 Turn OFF the 24V DC power supply for the master unit.
  • Page 4 [Functions] ■Function list Model Speci cations Connection targets Functions Address Detection of sensor cable NPN input: 2 points, Word disconnection Single unit Remote Word ASLINKER General-purpose NPN output: 2 points address address transmission transmission simpli ed address 2-wire type 3-wire type 2-wire sensors, switches NPN input: 1 point/output: 1 point...
  • Page 5 [How to Connect AnyWireASLINK] The AnyWireASLINK can employ a two-wire or four-wire terminal selectively depending on the load current. If the load current is small, using a two-wire (non-isolated) terminal allows for achieving simpli ed wiring without local power supply. In the case of prioritizing the sites of concentrated loads and/or the number of connections, hybridization with a four-wire (isolated) terminal, which supports local power supply, is also possible.
  • Page 6 Product Type Allowable power current ASLINK lter ANF-01 MAX 5A/24V DC Filter of COSEL Co., Ltd. EAC-06-472 MAX 6A/24V DC ■AnyWire Type: ANF-01 Connection example ①Power supply to the entire system 2-wire 4-wire 4-wire terminal terminal terminal AnyWireASLINK master POWER IN...
  • Page 7 ■COSEL Co., Ltd. Type: EAC-06-472 Connection example ① Power supply to the entire system 2-wire 4-wire 4-wire terminal terminal terminal AnyWireASLINK master When using this lter, please be careful of the positions of LOAD and LINE. LOAD LINE Terminator EAC-06-472 If the total length of the section where all the DP, DN, 24V, and 0V lines run in parallel is more than 50m General-purpose power supply lter...
  • Page 8 [Name of Each Part] LED indicators LINK : Transmission indicator (Green) ■Input I/O connection line : Input indicator (Orange) Transmission line : Input indicator (Orange) Brown: 24VL connection wire : Alarm indicator (Red) Black: IN0 Blue: 0VL LINK Brown: 24VL Black: IN1 Blue: 0VL Setting port...
  • Page 9: Address Setting

    [Various Settings] Address setting Parameter setting ■Common procedure for address writer operation Be sure to connect to the AnyWireASLINK master unit to use. An address writer ARW-04 (Ver. 04-1.01 or later version) or ARW-03 (Ver. 2.10 or later version) is required for operation. For the details of the operating method, refer to the product guide of the address writer.
  • Page 10 Parameter setting ■Disconnection monitoring function setting [Equipment parameter 1] This parameter is used to specify whether the I/O cable disconnection detecting function is enabled or disabled. Variable Description I/O disconnection detection and short-circuit detection are disabled. I/O disconnection detection and short-circuit detection are enabled. Factory setting: 0 ■Operation modes available with each model Detection of I/O disconnection...
  • Page 11 [Monitor Display] LED name Display status Description Transmission signal error Model mismatching error * LINK Transmission signal received Flashing LINK (Green) (Green) Setting port I/O0 (Orange) No transmission signal (disconnection and Unlit reverse connection of DP and DN lines included) LINK I/O0 I/O0...
  • Page 12 [Troubleshooting] < LINK does not ash > Things to be checked Remedy Check the connection of this unit. Disconnect this unit once, and then reconnect it. Check conditions of the master unit 1) If LINK on the master unit is ashing and LINK on the slave unit is lit, it is possible that the master and slave unit.
  • Page 13 [Configuration and Electrical Characteristics of the Input and Output Circuits] 2-wire (non-isolated) NPN input B281SB-02U-CC20 / B281XB-02U-CC20 (Input) <Circuit conditions> 24VL: Brown Rated input voltage: 24V DC Max. switching current: 3.5mA ON current: 2.2mA or more 6.8k IN: Black OFF current: 1mA or less ON voltage: 16V or more (24VL-IN)
  • Page 14 2-wire (non-isolated) PNP input B281SB-02US-CC20 / B281XB-02US-CC20 (Input) <Circuit conditions> 24VL: Brown Rated input voltage: 24V DC Max. switching current: 3.5mA ON current: 2.2mA or more Switch, sensor, etc. OFF current: 1mA or less (2-wire type) ON voltage: 16V or more (IN-0VL) 6.8k OFF voltage: 8V or less (IN-0VL)
  • Page 15 [Equipment Parameter and Its Setting] Equipment Setting item Description Variable Description parameter I/O disconnection detection and Used to specify whether the I/O cable Disconnection 0000 short-circuit detection disabled disconnection detecting function is monitoring function enabled or disabled. I/O disconnection detection and setting 0001 Factory setting: 0000...
  • Page 16 ■ ADP-81 (Mounting adaptor) Connection hook 40.2 10.4 Connection hook -B281*B02U*CC20 16/17-...
  • Page 17 [Address] Anywire Corporation Headquarters :1 Babazusho, Nagaokakyo-shi, Kyoto 617-8550 JAPAN Contact :Contact by mail info_e@anywire.jp :Contact by website http://www.anywire.jp Printed in Japan 2013,2014,2016,2017,2018,2019,2020 UMA-08717AP-EN -B281*B02U*CC20 17/17-...