Water Supply Connection - Characteristics; Water Supply Characteristics; Steam Evacuation - Bartscher Deltamat TF527 LPR Manual

Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 30

7.2.3 Water supply connection - Characteristics

Fresh water supply features:
Table 1
Connect the machine's water supply with an interrupt valve capable of quickly and completely shutting off water intake.
*It is compulsory to install a water-softener, in case of water with average hardness above
be cleaner and the machine will last much longer.
The machine can be equipped with a water softener, on request. If the machine is equipped with a water-softener, a
regeneration of the resins shall be done on regular basis (see par.
N.B.:
Any damage caused by limestone (calcareous water higher-up than 8°f and without water-softener) will not be covered
by warranty.
A periodical check of the supplied water hardness is highly recommended.
**Machines shall be made with extra power in case of cold water infeed.
***The water supply temperature shall never exceed 55°C.

7.2.4 Water supply characteristics

The machine water supply must be potable, in compliance with Directive 98/83/EC.
The inlet water must also meet the parameters given in the table 2.
Water parameters table
Chlorine
pH
Water hardness
Iron
Table 2
Manganese
Out of range values might lead to corrosion and jeopardize the life of the machine.
1
2
Should the water hardness is higher
Out of range values might lead scaling and sediments with a consequent lower performance, functionality, and expected
3
life of the machine.
Desired value: Out of range values might lead stainless steel blackening/tarnishing.
4
It is recommended a water test once a year.

7.2.5 Steam evacuation

In accordance with regulations of environmental hygiene, for the proper functioning of the machine and a healthy environment
for the operator who working in there, it should be at least 10 air volume changes per hour in the room where the machine
is installed.
For small wash rooms we recommend at least 15 air volume changes per hour.
Water characteristics table
Static Pressure
Dynamic Pressure*
Water hardness**
Cold water-supply temperature***
Hot water-supply temperature****
Capacity
1
3
4
it is compulsory
3.6 Regeneration
to install a water softener and check periodically its operation.
Min
200kPa
400kPa
150kPa
350kPa
2°f
5°C
50°C
10l/min
8°f. Washed objects will
device).
Min
6,5
1
0,05 mg/l
EN
Max
8°f
50°C
60°C
Max
2mg/l
8,5
3
8°f
2-3
0,2 mg/l
page 49

Advertisement

Table of Contents
loading

This manual is also suitable for:

111678111679Tf527 lpr

Table of Contents