Page 1
How to Use Your Sentrol Security System Z X L C D/ Z X V F D Control Station VIEW INFO ALM MEM EVENT LOG CANCEL BYPASS DELAY ARM CHIME AWAY RST SMOKE TEST PROGRAM QUIT ACCESS INSTANT STAY CLEAR...
TABLE OF CONTENTS Table of Contents Operating Your System ..........5 Optional Features ............ 16 Alarm Conditions ............. 24 Trouble Conditions ..........25 Testing Your System ..........26...
Page 4
TABLE OF CONTENTS ZX200/ZX210 Programming ........32 ZX400/ZX410/ZX440F Programming ....... 36 Multi-Area Operation ..........52 Common Area Operation ......... 53 Fire Detection ............54 System Reference Guide .......... 58 Protection Zones ............. 60 Owners Insurance Premium Credit Requested Form ..61 FCC Compliance ............
OPERATING YOUR SYSTEM Operating Your System The LCD & VFD Control Station VIEW INFO ALM MEM EVENT LOG CANCEL BYPASS DELAY ARM CHIME AWAY RST SMOKE TEST PROGRAM QUIT ACCESS INSTANT STAY CLEAR ENTER HOME NEXT NIGHT (ZXLCD and ZXVFD)
Page 6
OPERATING YOUR SYSTEM The Control Station Keys View Info Key Alarm Memory Key Event Log Key - (ZX400/ZX410/ZX440F only) Bypass Key Delay Arm Key - (ZX400/ZX410/ZX440F only) Chime Key Reset Smoke Key Test Key Program Key Access Key Quit Key CLEAR Instant Key ENTER...
Page 7
OPERATING YOUR SYSTEM Armed Status Indicator AWAY AWAY STAY STAY NIGHT NIGHT Panic Keys PAGER...
Page 8
OPERATING YOUR SYSTEM The Control Station Display READY TO ARM ZX200/ZX210 A1 READY TO ARM JAN 21 05:27:52 ZX400/ZX410/ZX440F...
Page 9
OPERATING YOUR SYSTEM Turning Your System ON A1 READY TO ARM READY TO ARM JAN 21 05:27:52 ZX200/ZX210 ZX400/ZX410/ZX440F AWAY STAY NIGHT TO ARM AWAY ENTER PASSCODE ARMED AWAY AREA 1 ARMED AWAY ZX200/ZX210 ZX400/ZX410/ZX440F...
Page 10
OPERATING YOUR SYSTEM Turning Your System OFF CANCEL CANCEL TO TURN OFF ENTER PASSCODE Entry Time...
Page 11
OPERATING YOUR SYSTEM When a Burglar Alarm Occurs Scenario 1: You accidentally set off the alarm system. Scenario 2: An alarm goes off in the middle of the night.
Page 12
OPERATING YOUR SYSTEM Scenario 3: You arrive at the premises and the system’s bell is sounding. Scenario 4: You arrive at the premises and the system is in alarm, but the bell is off.
Page 13
OPERATING YOUR SYSTEM System Not Ready Changing The Security Level AWAY STAY NIGHT TO ARM AWAY ENTER PASSCODE...
Page 14
OPERATING YOUR SYSTEM Exit While Armed Chime TO SET CHIME ENTER PASSCODE...
Page 15
OPERATING YOUR SYSTEM Viewing and Printing The Event Log (ZX400/ZX410/ZX440F only) FOR EVENT LOG ENTER PASSCODE ENTER 1=VIEW 2=PRINT CANCEL CLEAR...
OPTIONAL FEATURES Optional Features Bypass - (DO NOT enable for UL Listed Systems) Group Bypass - (to intentionally bypass all open zones) TO BYPASS ZONES ENTER PASSCODE ZONE __ ENTER ZONE 99 - BYPASS FAULTED ZONES ZONE __ ENTER CLEAR...
Page 17
OPTIONAL FEATURES BYPASSING COMPLETE Selective Bypass/Unbypass - (to intentionally bypass/unbypass a specific zone) TO BYPASS ZONES ENTER PASSCODE ZONE __ ENTER ZONE __ - BYPASS ZONES ENTER CLEAR BYPASSING COMPLETE...
Page 18
OPTIONAL FEATURES Removing Bypass TO BYPASS ZONES ENTER PASSCODE ZONE __ ENTER ZONE 00 - ALL ZONES UNBYPASSED ZONE __ ENTER CLEAR BYPASSING COMPLETE...
Page 19
OPTIONAL FEATURES Force-Arming - (DO NOT enable for UL Listed Systems) AWAY STAY NIGHT TO ARM AWAY ENTER PASSCODE CANNOT ARM AREA 1 FORCE ARM AWAY FORCE ARM AWAY ZX200/ZX210 ZX400/ZX410/ZX440F Turning Your System ON Using Two Button/ Double Press...
Page 20
OPTIONAL FEATURES Exit-ON (ZX400/ZX410/ZX440F only) 9 MIN 59 SEC UNTIL AUTO ARM Automatic-ON - (DO NOT enable for UL Listed Systems) (ZX400/ZX410/ZX440F only) Delay Automatic-ON (ZX400/ZX410/ZX440F only) TO DELAY ARM ENTER PASSCODE AUTO ARM DELAYED...
Page 21
OPTIONAL FEATURES NO AUTO ARM TO DELAY Keyswitch Operation Access Output (This system is not UL Listed for Access Control) FOR ACCESS ENTER PASSCODE...
Page 22
OPTIONAL FEATURES Duress AWAY AWAY STAY NIGHT NIGHT STAY CANCEL Duress Panic Keys PAGER User On Premise...
Page 23
OPTIONAL FEATURES Secondary Function Keys (ZX400/ZX410/ZX440F only) ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER...
TESTING YOUR SYSTEM Testing Your System Walk Verifies that all system zones are operating properly Battery Verifies that the system battery is fully charged Bell Verifies that the system audibles are operating properly Communicator Verifies that the system communicates with the Central Station Keypad Verifies that the Control Station lights operate properly...
Page 27
TESTING YOUR SYSTEM CLEAR Battery Test FOR TESTS ENTER PASSCODE ENTER 1-6 TO SELECT A TEST LOW/NO BATTERY OFF TO SILENCE...
Page 28
TESTING YOUR SYSTEM Bell Test FOR TESTS ENTER PASSCODE ENTER 1-6 TO SELECT A TEST BELL TEST...
Page 29
TESTING YOUR SYSTEM Communicator Test FOR TESTS ENTER PASSCODE ENTER 1-6 TO SELECT A TEST TESTING COMMUNICATIONS COMM TEST PASSED COMM FAILURE OFF TO SILENCE...
Page 30
TESTING YOUR SYSTEM Keypad Test FOR TESTS ENTER PASSCODE ENTER 1-6 TO SELECT A TEST KEYPAD TEST...
Page 31
TESTING YOUR SYSTEM RF Signal Strength FOR TESTS ENTER PASSCODE ENTER 1-6 TO SELECT A TEST DEVICE 00 SELECT RF DEVICE ENTER DEVICE 13 DEVICE 13 NO DEVICE LOW SIGNAL The selected zone is not RF or is missing. Call your Installation Representative. DEVICE 13 DEVICE 13 ACCEPTABLE...
ZX200/ZX210 PROGRAMMING ZX200/ZX210 Programming Remote Connect Allows the installer to program and diagnose problems from a remote site using the telephone lines. Program User Codes Allows you to change any passcodes. Remote Connect Programming the User Passcodes TO PROGRAM ENTER PASSCODE SELECT PROGRAM OPTION 1-2...
Page 33
ZX200/ZX210 PROGRAMMING USER 00 SELECT USER ID ENTER CLEAR ENTER...
Page 34
ZX200/ZX210 PROGRAMMING Programming the Zone Names ENTER CLEAR ZONE 00 SELECT ZONE ID ENTER...
Page 35
ZX200/ZX210 PROGRAMMING Character Available CLEAR ENTER CLEAR...
ZX400/ZX410/ZX440F PROGRAMMING ZX400/ZX410/ZX440F Programming Remote Connect Allows the installer to program and diagnose problems from a remote site using the telephone lines. Set Clock Sets the system date and time. (Military format) Program Automatic-ON Schedules your system to automatically turn ON at a specific day(s) and time(s).
Page 37
ZX400/ZX410/ZX440F PROGRAMMING Set Clock TO PROGRAM ENTER PASSCODE SELECT PROGRAM OPTION 1-8 10:53 02/04/97 ENTER = COMPLETE ENTER CLEAR...
Page 38
ZX400/ZX410/ZX440F PROGRAMMING Programming the Automatic-ON Feature (DO NOT enable for UL Listed Systems) A. Setting the Security Level TO PROGRAM ENTER PASSCODE SELECT PROGRAM OPTION 1-8 LOCATION: 00 VALUE: ENTER ENTER...
Page 39
ZX400/ZX410/ZX440F PROGRAMMING B. Day(s) To Turn ON LOCATION: 00 VALUE: ENTER ENTER...
Page 40
ZX400/ZX410/ZX440F PROGRAMMING C. Hour To Turn ON Each Day LOCATION: 00 VALUE: ENTER ENTER...
Page 41
ZX400/ZX410/ZX440F PROGRAMMING D. Minute To Turn ON Each Day LOCATION: 00 VALUE: ENTER ENTER CLEAR...
Page 42
ZX400/ZX410/ZX440F PROGRAMMING Programming the Latch Key Feature A. Setting the Latch Key User ID to be Monitored TO PROGRAM ENTER PASSCODE SELECT PROGRAM OPTION 1-8 LOCATION: 00 VALUE:...
Page 43
ZX400/ZX410/ZX440F PROGRAMMING ENTER ENTER B. Day(s) of Week to Monitor LOCATION: 00 VALUE: ENTER ENTER...
Page 44
ZX400/ZX410/ZX440F PROGRAMMING C. Latch Key Time Window LOCATION: 00 VALUE: ENTER ENTER...
Page 45
ZX400/ZX410/ZX440F PROGRAMMING D. Hour To Be Monitored For Each Day LOCATION: 00 VALUE: ENTER ENTER...
Page 46
ZX400/ZX410/ZX440F PROGRAMMING E. Minute To Be Monitored For Each Day LOCATION: 00 VALUE: ENTER ENTER CLEAR...
Page 47
ZX400/ZX410/ZX440F PROGRAMMING Programming the User Passcodes TO PROGRAM ENTER PASSCODE SELECT PROGRAM OPTION 1-8 USER 00 SELECT USER ID ENTER CLEAR...
Page 48
ZX400/ZX410/ZX440F PROGRAMMING Cancelling the Automatic-ON for Today for today only TO PROGRAM ENTER PASSCODE SELECT PROGRAM OPTION 1-8 AUTO ARM ABORTED TODAY NO AUTO ARM TO ABORT...
Page 49
ZX400/ZX410/ZX440F PROGRAMMING Cancelling Exit-ON for Today for today only TO PROGRAM ENTER PASSCODE SELECT PROGRAM OPTION 1-8 EXIT ARM ABORTED TODAY...
Page 50
ZX400/ZX410/ZX440F PROGRAMMING Programming the Zone Names TO PROGRAM ENTER PASSCODE SELECT PROGRAM OPTION 1-8 ZONE 00 SELECT ZONE ID ENTER...
Page 51
ZX400/ZX410/ZX440F PROGRAMMING Character Available CLEAR ENTER CLEAR...
MULTI-AREA OPERATION Multi-Area Operation (ZX400/ZX410/ZX440F only) AWAY ENTER 1=AREA1 2=AREA2 3=BOTH A1 READY TO ARM JAN 21 05:27:52 AREA 2 ARMED AWAY...
SYSTEM REFERENCE GUIDE System Reference Guide Emergency Numbers Police Fire Neighbor Doctor Central Station Service Rep. Central Station Subscriber Number Delay Times Control Station Location...
Page 59
SYSTEM REFERENCE GUIDE Features Enabled Bypassing Exit-ON Hold Up Force-Arming Automatic-ON Auxiliary Alarm Double Press ON Keyswitch User On Premise Two Button ON Household Fire Intrusion...
Owners Insurance Premium Credit Requested This form should be completed and forwarded to your homeowners insurance carrier for possible premium credit. This control is UL Listed for: UL Grade A Household Burglary UL Household Fire Warning System A. General Information: Insureds Name and Address Insurance Co.
Page 62
E. Smoke Detector Locations Furnace Room Kitchen Bedrooms Attic Basement Living Room Dining Room Hall Other F. Burglary Detecting Device Locations: Front Door Basement door All Exterior Doors Rear Door 1st Floor windows All Windows Interior Locations Other All Accessible Openings, Including Skylights, Air Conditioners and Vents G.
FCC COMPLIANCE FCC Compliance Part 68 Notification This equipment complies with Part 68 of the Federal Communications Commissions (FCC) rules. All connections to the telephone net work must be made through standard telephone company plugs and jacks, RJ31-X or equivalent, in such a manner as to allow for easy and immediate disconnection of the equipment.
Need help?
Do you have a question about the ZXLCDL and is the answer not in the manual?
Questions and answers