Performing auto calibration
For details on the auto calibration, see "9:
Calibrating the appropriate speaker settings
automatically (Auto Calibration)" (page 46).
Refer to "Before you perform the auto
calibration" (page 46) before performing the
auto calibration.
To operate on the receiver
1
Press SHIFT, then press MENU to set
the GUI display mode to off.
The menu appears on the TV screen when
"GUI MODE" appears on the display.
2
Press AMP.
Receiver operation is enabled.
3
Press MENU.
"Auto Calibration" is displayed.
4
Press
.
5
Press V/v repeatedly to select "AUTO
CAL START?," then press
the measurement.
Measurement starts in five seconds. A
count down is displayed.
Note
While the time is counting down, stand away
from the measurement area to avoid
measurement error.
6
Measurement starts.
The measurement process will take
approximately 30 seconds. Wait until the
measurement process completes.
To cancel auto calibration, change the volume,
activate the MUTING function, switch
functions, change the setting of the
SPEAKERS switch of the receiver, or connect
headphones.
Note
You cannot measure the speaker height of the
surround speakers and the surround back speakers.
Set this value from "SP POSI." settings in the
Speaker settings menu.
120
GB
Tips
• Operations other than turning the receiver on or off
are deactivated during auto calibration.
• In the following situations, the measurements may
not be performed correctly or auto calibration
cannot be performed.
– when special speakers, such as dipole speakers
are used.
– when the multi zone function is used in zone 2.
To confirm/save auto calibration
when GUI function is turned off
1
Confirm the measurement result.
When the measurement ends, a beep
sounds and the measurement result appears
on the display.
Measurement
result
When the
measurement
process
completes
properly
When the
to start
measurement
process fails
2
Press V/v repeatedly to select the item,
then press
The measurement results are saved.
Item
RETRY
SAVE EXIT
WRN CHECK
PHASE INFO
DIST.INFO
Display
Explanation
COMPLETE Proceed to step
2.
ERROR
See "Message
CODE 3x
list after auto
calibration
measurement"
(page 51).
.
Explanation
Re-performs the auto
calibration.
Saves the measurement
results and exits the setting
process.
Displays a warning
concerning the measurement
results. See "When you select
"WRN CHECK"" (page 51).
Displays the phase of each
speaker (in phase/out of
phase). See "When you select
"PHASE INFO"".
Displays the measurement
result for speaker distance.