Page 2
3. Spring 4. Hexagonal head To assembly the four parts after clearing. Step 3: Magnet Parts There is magnet parts in the float. *The magnet can not be turnned and not be separated. New-Flow Paddle Wheel Liquid Flow Meter Instruction Manual...
Page 3
1. Float 2. Magnet 1 2 3 3. Spring 4. Hexagonal head and tight Hexagnal head Step 6: Adjustment the indicator of zero. (Please adjustinpg while the indicating pointer did not indicate on zero at scale). New-Flow Flow Switch Instruction Manual...
Page 4
Step 7: The model OF100 completed picture. Note.: IF indicator shows the scale over 100% flow after installing. It means that is a wrong way. Please dismantle all parts and overturn the magnet in 180˚. Then assembling as step 5 again.