JACUZZI COMET CLEANER
//
Troubleshooting Guide
Symptom
Power Supply
The power supply is not
working/responding to pushing buttons
LED Indicators
All three LED indicators on power
supply are flashing
Only one LED indicator on the power
supply is flashing
LED indicators are not flashing/not
working even after selecting cycle
setting
Movement
Cleaner is floating on the surface of the
water, not sinking to/staying on pool
floor
Cleaner will only travel halfway across
pool, then stops completely
Cleaner stops/gets stuck at walls/stairs
Cleaner does not move at all
Cleaner is moving in circles
Cable has excessive tangling
Possible Reason
1.
Control panel is damaged
2.
Power switch & PCB are
damaged
3.
Power supply is unplugged
The cleaner has finished current cycle
The cleaner is running automatically
Control panel is damaged
Cleaner was deployed without exhausting
the air inside it completely
1.
Nozzle is on backwards, causing
friction between impeller and
water channel, which warns
cleaner to stop
2.
Power unit has failed
3.
Motor has failed
4.
Cable is broken
Toothed clutch between impeller and
axle sleeve is engaged improperly
1.
Power unit has failed
2.
Motor has failed
3.
Cable is broken
Improper nozzle angle is set
Improper nozzle angle is set
Corrective Action
1.
Replace control panel
2.
Replace power switch & PCB
3.
Check to ensure power supply
cord is plugged in
Power off the cleaner
No action required
Replace control panel
Deploy the cleaner only after exhausting
the air inside it completely
1.
Reinstall nozzle
2.
Replace power switch & PCB
3.
Replace motor
4.
Replace cable
Replace impeller and axle sleeve
1.
Replace power switch & PCB
2.
Replace motor
3.
Replace cable
Adjust nozzle angle
Adjust nozzle angle