LOWER OVEN INFORMATION

ELECTRONIC OVEN CONTROL

ELECTRONIC OVEN CONTROL (EOC) FAULT CODE DESCRIPTIONS
Fault Code
Likely Failure Condition/Cause
Series
(F10) Control has sensed a potential
F1
runaway oven condition. Control
may have shorted relay, RTD sensor
probe may have gone bad.
(F11) Shorted keypad.
(F13) Control's internal checksum may
have become corrupted.
(F14) Misconnected flat cables.
(F30) Open RTD sensor probe/ wiring
F3
problem. Note: EOC may initially
display an "F1", thinking a
runaway condition exists.
(F31) Shorted RTD sensor probe / wiring
problem. Note: "F3" is displayed
when oven is in active mode or an
attempt to enter an active mode is
made.
(F90 Door motor mechanism failure.
F9
to
F94)
Suggested Corrective Action
1. Check RTD sensor probe and replace if necessary. If oven is
overheating, disconnect power. If oven continues to overheat
when the power is reapplied, replace EOC. Severe overheating
may require the entire oven to be replaced, should damage
be extensive.
2. Press CLEAR key.
3. Disconnect power, wait 30 seconds and reapply power. If
fault returns upon power-up, replace EOC.
4. Disconnect power; verify flat cable connections (P6 or P12).
1. Press CLEAR key.
2. Check wiring in probe circuit for possible open condition.
Check RTD resistance at room temperature (compare to
probe resistance chart). If resistance does not match the
chart, replace the RTD sensor probe.
3. Let the oven cool down and restart the function
1. Press CLEAR key.
2. If CLEAR key does not eliminate problem, turn off power for
30 seconds, then turn on power.
3. Check wiring of Lock Motor, and Lock Switch and Door
Switch circuits.
4. Unplug P5, apply power (L1) directly to the Lock Motor, if the
motor does not rotate, replace Lock Motor Assembly. Plug
P5.
5. Check Lock Switch A for proper operation (do they open and
close, check with ohmmeter). The Lock Motor may be
powered as in above step to open and close Lock Switch. If
the Lock Switch is defective, replace Motor Lock Assembly.
6. If all above steps fail to correct situation, replace control.