EPAC300-M50 SERIES CONTROLLER SPECIFICATIONS
5.1 EPAC300-M50 Series
• Temperature Range:
• Service Voltage:
• Power Consumption:
• Physical Dimensions:
• Weight:
5.2 EPAC300-M50 Series Power Supply
• Input:
• Outputs:
• Safety:
• Short Out:
• Backup:
• Timing:
5.3 EPAC300-M50 Series Input / Output Assembly
• Inputs and Outputs meet or exceed NEMA TS-2 Electrical Specification
• Port 1 communications meet or exceed EIA-485 electrical specification
• Port 2 Communications meet or exceed EIA-232 electrical specification
5.4 Internal 1200 BPS NEMA Port 3 FSK Modem (optional)
• Data Rate:
• Modulation:
• Data Format:
• Line:
• Tone Frequencies:
• Duplex:
• Anti-Streaming:
• Transmit Power:
• Sensitivity:
• RTS to CTS Delay:
AUGUST 2005
EPAC300-M50 SERIES USER'S MANUAL
SECTION 5
-37 to +74 C (Operating)
89 to 135 VAC, 57 to 63 Hz
176 to 264 VAC, 47 to 53 Hz (Optional)
25 Watts Typical, 120 Watts Max (Full Expansion)
7" H x 9.5" D x 15.5" W
2 pounds
89-135 VAC, 57 to 63 Hz
176 to 264 VAC, 47 to 53 Hz (Optional)
+5, +/-12 VDC, (all versions), +24 VDC (M52 only)
Power Fail / Restart, Overvoltage, Overload Protection
Storage Capacity to Ride Through 500 mS Power Outages
Super Capacitor backup for clock, SRAM (no batteries)
60 Hz Service Reference, Compensation for Missing Pulses
300 to 1200 bps
Phase coherent frequency shift keying (FSK).
Asynchronous, serial by bit.
Type 3002 voice-grade, unconditioned.
1.2 KHz MARK, 2.2 KHz SPACE
Full duplex (4-wire) or half duplex (2-wire), programmable
7-seconds or disabled, programmable
4 volt peak to peak amplitude, no adjustment
Factory set receiver sensitivity, no adjustment
13 mS factory set, no adjustments