DOOR / LID AJAR ALARM
The door/lid alarm will activate if it is ajar for more than five (5)
minutes. The control panel will beep every five (5) seconds, the red
alarm light will glow and the display will alternate between "d"
(DOOR/LID) and the cabinet temperature (see figure 7). Press the
ALARM RESET button to turn the audible alarm (beep) off. The
display will keep flashing and the red light will stay on. Close the
door/lid of the freezer to return it to normal operation.
POWER FAILURE
If power to the freezer is lost, the power loss alarm will activate. The
display will be off but the control panel will beep every minute (see
figure 8). To turn the audible alarm (beep) off, press the ALARM
RESET button. The audible alarm will also turn off automatically
when power is reconnected to the freezer. The temperature alarm
will activate if the temperature of the cabinet rises to al level above
23ºF (-5ºC) during power failure. The red alarm light however, will
not illuminate.
SYSTEM ERROR ALARM
The display will alternate between temperature and "CE" or "E"
and the control panel will beep every five (5) seconds (see figures
9 and 10). Press the ALARM RESET button to turn the audible
alarm (beep) off. Call service repair to correct the problem.
Figure 7
Figure 8
Figure 9
Figure 10

ALARM FUNCTION TABLE

Except during power loss, the red alarm light illuminates
whenever there is an alarm status.
Display Status
Cabinet
temperature is
displayed.
FF is displayed.
Temperature
flashing on and
off. Control panel
beeps every 5
seconds.
Alternating: "d"
and temperature.
Control panel
beeps every 5
seconds.
Alternating: "E"
and temperature.
Control panel
beeps every 5
seconds.
Alternating: "CE"
and temperature.
Control panel
beeps every 5
seconds.
Display off.
Display Lock/Unlock: Press and hold ALARM RESET until the
control panel beeps to lock or unlock the display.
FI
RST
3
Function
Response
Normal
None
Operation
Extreme Freeze
None
Freezer
Check power is
temperature too
connected.
high
Contact service
technician. Press
ALARM RESET to
shut off audible
alarm (beep).
Door ajar
Close door. Press
ALARM RESET to
stop audible alarm
(beep).
Operational error
Contact service
technician. Press
ALARM RESET to
stop audible alarm
(beep).
Operational error
Contact service
technician. Press
ALARM RESET to
stop audible alarm
(beep).
Power failure
Reconnect power
connection.