Location Of Your Dryer - Frigidaire AGQ8000FG Installation Instructions Manual

Gas & electric dryer
Hide thumbs Also See for AGQ8000FG:
Table of Contents

Advertisement

Available languages

Available languages

Venting vertical through a roof may expose the exhaust system to down
drafts causing an increase in vent restriction.
Running the exhaust system through an uninsulated area may cause
condensation and faster accumulation of lint.
Compression or crimping of the exhaust system will cause an increase in
vent restriction.
The exhaust system should be inspected and cleaned a minimum of every 18
months with normal usage. The more the dryer is used, the more often you
should check the exhaust system and vent hood for proper operation.
All dryers shipped from the factory are set up for rear exhausting. However, on
electric dryers, exhausting can be to the right or left side of the cabinet or the
bottom of the dryer. On gas dryers, exhausting can be to the right side of the
cabinet or the bottom of the dryer. Directional exhausting can be accomplished
by installing Exhaust Kit, P/N 131456800, available through your parts distribu-
tor. Follow the instructions supplied with the kit.
EXHAUST DUCT LOCATING DIMENSIONS
3 3/4"
3 3/4"
3 3/4"
3 3/4"
3 3/4"

LOCATION OF YOUR DRYER

DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather conditions.
2. In an area where it will come in contact with curtains, drapes, or anything
that will obstruct the flow of combustion and ventilation air.
3. On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.54 cm).
INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be
exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the
Gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. A minimum of 120 square inches (774.2 square cm) of opening, equally
divided at the top and bottom of the door, is required. Air openings are
required to be unobstructed when a door is installed. A louvered door with
equivalent air openings for the full length of the door is acceptable.
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
Alcove 0 (0 cm) 0 (0 cm)
Closet
0 (0 cm) 0 (0 cm)
Closet door ventilation required: 2 louvered openings each 60 square inches
(387 square centimeters) — 3 inches (7.6 cm) from bottom and top of door.
This dryer MUST be exhausted outdoors.
5. The following illustrations show minimum clearance dimensions for proper
operation in a recess or closet installation.
EXHAUST DIRECTION
SAME AS OTHER SIDE
SAME AS OTHER SIDE
SAME AS OTHER SIDE
SAME AS OTHER SIDE
SAME AS OTHER SIDE
5 7/8"
5 7/8"
5 7/8"
5 7/8"
5 7/8"
13 1/2"
13 1/2"
13 1/2"
13 1/2"
13 1/2"
3 3/4"
3 3/4"
3 3/4"
3 3/4"
3 3/4"
TOP FRONT
1 (2.54 cm)
4 3/8"
4 3/8"
4 3/8"
4 3/8"
4 3/8"
(9.5 cm)
(9.5 cm)
(9.5 cm)
(9.5 cm)
(9.5 cm)
5
60 sq. inches
(387.1 sq. cm)
60 sq. inches
(387.1 sq. cm)
CLOSET DOOR
0" (0 cm)
0" (0 cm)
1"
0" (0 cm)
(2.54 cm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agq6700fe - 27" gas dryer

Table of Contents