2.3

Mounting the Device

The RUGGEDCOM RX1511 is designed for maximum mounting and display flexibility.
It can be equipped with connectors that allow it to be installed in a 35 mm (1.4 in)
DIN rail, or directly on a panel.
Heat generated by the device is channeled outwards from the enclosure. As such, it
is recommended that 2.5 cm (1 in) of space be maintained on all open sides of the
device to allow for some convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a
reduction of ambient temperature and improve the long-term reliability of all
equipment mounted in the rack space.
Note
For detailed dimensions of the device with either DIN rail or panel hardware installed,
refer to
2.3.1

Mounting the Device on a DIN Rail

For DIN rail installations, the RUGGEDCOM RX1511 can be equipped with panel/DIN
rail adapters pre-installed on each side of the chassis. The adapters allow the device
to be slid onto a standard 35 mm (1.4 in) DIN rail.
RUGGEDCOM RX1511
Installation Manual, 04/2021, C79000-G8976-1056-20
Verify all items are included.
NOTICE
"Dimension Drawings (Page
46)".
Installing the Device
2.3 Mounting the Device