Converting to another gas type

Functional check

 Check all gas fittings for leaks.
 Reassemble the hob.
 Ignite all burners to check that they
are operating correctly.
– The flame must not go out on the
lowest setting, or when the control is
turned quickly from the highest to the
lowest setting.
– On the highest setting, the flame
must have a distinctive and visible
core.
 Adhere the label supplied with the
jets, stating the type of gas being
used.