Hirschmann MACH104-16TX-PoEP+2X Series User Manual

Hirschmann MACH104-16TX-PoEP+2X Series User Manual

Industrial ethernet workgroup switch.full gigabit.

Advertisement

Quick Links

User Manual
Installation
Industrial Ethernet Workgroup Switch
MACH104-PoEP Full Gigabit Family
x y
1
MACH104
FAULT
USB
V.24
FAULT
RM
Sb
P
2
MACH104-16TX-PoEP+2X...
MACH104-16TX-PoEP+2X-R...
MACH104-16TX-PoEP+2X-E...
x y
1
MACH104
FAULT
USB
V.24
FAULT
RM
Sb
P
2
MACH104-16TX-PoEP...
MACH104-16TX-PoEP-R...
MACH104-16TX-PoEP-E...
Installation MACH104-PoEP
Release 08 01/2019
3
5
7
9
11
6
8
10
12
4
3
5
7
9
11
6
8
10
12
4
13
15
17
19
21
14
16
18
20
13
15
17
19
14
16
18
20
https://hirschmann-support.belden.com
22
Technical support

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MACH104-16TX-PoEP+2X Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hirschmann MACH104-16TX-PoEP+2X Series

  • Page 1 User Manual Installation Industrial Ethernet Workgroup Switch MACH104-PoEP Full Gigabit Family MACH104 FAULT V.24 FAULT MACH104-16TX-PoEP+2X... MACH104-16TX-PoEP+2X-R... MACH104-16TX-PoEP+2X-E... MACH104 FAULT V.24 FAULT MACH104-16TX-PoEP... MACH104-16TX-PoEP-R... MACH104-16TX-PoEP-E... Installation MACH104-PoEP Technical support Release 08 01/2019 https://hirschmann-support.belden.com...
  • Page 2 In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Hirschmann Automation and Control GmbH Stuttgarter Str.
  • Page 3: Table Of Contents

    Contents Safety instructions About this manual Legend Description General device description Device name and product code Device variants available Device views 1.4.1 Front view 1.4.2 Rear view Supply voltage 1.5.1 MACH104-16TX-PoEP... und MACH104-16TX- PoEP+2X... 1.5.2 MACH104-16TX-PoEP-R... und MACH104-16TX- PoEP+2X-R... 1.5.3 MACH104-16TX-PoEP-E... und MACH104-16TX- PoEP+2X-E...
  • Page 4 Installation Checking the package contents Installing an SFP transceiver (optional) MACH104-16TX-PoEP-E..., MACH104-16TX-PoEP+2X-E...: Wiring and installation of the supply voltage Wiring and installing the signal contact Installing the device and grounding 2.5.1 Selecting the assembly location 2.5.2 Mounting on a flat surface 2.5.3 Mounting in a switch cabinet 2.5.4 Mounting on the wall 2.5.5 Grounding the device...
  • Page 5 Underlying technical standards Further support Installation MACH104-PoEP Release 08 01/2019...
  • Page 6: Safety Instructions

     Operate the device with undamaged components exclusively.  The device is free of any service components. In case of a damaged or malfunctioning device, turn off the supply voltage and return the device to Hirschmann for inspection. Qualification requirements for personnel ...
  • Page 7 Certified usage   Use the product only for the application cases described in the Hirschmann product information, including this manual.  Operate the product only according to the technical specifications. See “Technical data” on page 38.  Connect to the product only components suitable for the requirements of the specific application case.
  • Page 8  The power supply cable is suitable for the voltage, the current and the physical load. Hirschmann recommends a wire diameter of 0.5 mm² to 0.75 mm² (AWG20 up to AWG18).  This applies to the following device variants only: ...
  • Page 9 Prerequisites: Alternative 3 All of the following requirements are complied with:  The power supply complies with the requirements for a safety extra-low voltage (SELV) as per IEC/EN 60950-1.  Supply with DC voltage: A fuse suitable for DC voltage is located at both voltage inputs in the plus conductor of the power supply.
  • Page 10 In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany The product can be used in the industrial sector.
  • Page 11 Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations. These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment. The device creates and uses high frequencies and can also radiate these frequencies.
  • Page 12: About This Manual

     Command Line Interface reference manual The Network Management Software Industrial HiVision provides you with options for smooth configuration and monitoring. You find further information on the Internet at the Hirschmann product pages: http:// www.hirschmann.com/en/QR/INET-Industrial-HiVision Installation MACH104-PoEP Release 08 01/2019...
  • Page 13: Legend

    Legend The symbols used in this manual have the following meanings:  Listing Work step   Subheading Installation MACH104-PoEP Release 08 01/2019...
  • Page 14: Description

    The device provides you with a large range of functions, which the manuals for the operating software inform you about. You can download these manuals as PDF files from the Internet on the Hirschmann product pages (www.hirschmann.com). The Hirschmann network components help you ensure continuous communication across all levels of the company.
  • Page 15: Device Name And Product Code

    Device name and product code The device name corresponds to the product code. The product code is made up of characteristics with defined positions. The characteristic values stand for specific product properties. Item Product Characteristi Description characteristic c value 1 ... 17 Basic properties MACH104- Industrial Ethernet Workgroup Switch with:...
  • Page 16: Device Views

    Device views 1.4.1 Front view MACH104 FAULT V.24 FAULT LED display Device Status elements Signal contact USB interface V.24 interface Ports 1 ... 4 1000-Mbit/s Combo Ports Ports 5 to 12 1000-Mbit/s Twisted-Pair Ports with PoE+ Ports 13 to 20 1000-Mbit/s Twisted-Pair Ports with PoE+ Ports 21, 22 10-Gbit/s F/O ports...
  • Page 17: Rear View

    1.4.2 Rear view Non-heating Connecting the supply voltage appliance socket Table 4: Front view of device variants: MACH104-16TX-PoEP... MACH104-16TX-PoEP+2X... Non-heating Connecting the supply voltage appliance socket  Supply voltage 2 Non-heating Connecting the supply voltage appliance socket  Supply voltage 1 Table 5: Front view of device variants: MACH104-16TX-PoEP-R...
  • Page 18: Supply Voltage

    Supply voltage Note: Note the safety instructions in “Requirements for connecting electrical wires” on page Note: Observe the information about the voltages to be connected: “Technical data” on page 38 1.5.1 MACH104-16TX-PoEP... und MACH104-16TX- PoEP+2X... For the supply voltage, the following applies: ...
  • Page 19: Ethernet Ports

    Ethernet ports You can connect end devices and other segments to the device ports using twisted pair cables or optical fibers (F/O). 1.6.1 10/100/1000 Mbit/s twisted pair port This port is an RJ45 socket. The 10/100/1000 Mbit/s twisted pair port allows you to connect network components according to the IEEE 802.3 10BASE-T/100BASE-TX/ 1000BASE-T standard.
  • Page 20: 1000 Mbit/S F/O Port

    This port supports:  Full or half duplex mode Default setting: Full duplex 1.6.3 1000 Mbit/s F/O port This port is an SFP slot. The 1000 Mbit/s F/O port offers you the ability to connect network components according to the IEEE 802.3 100BASE-SX/1000BASE-LX standard.
  • Page 21: Combo Ports

    The PoE support complies with the following technical standards: Standard Description IEEE 802.3af Brief description Classes max. Powered Device (PD) class 0 (15.4 W) IEEE 802.3at Brief description PoE Plus Classes Max. Powered Device (PD) class 4 (30 W) Table 9: PoE support: technical standards The following applies to PoE ports: ...
  • Page 22: Sfp/Xfp Transceiver

    Both Fast Ethernet SFP transceivers and Gigabit Ethernet SFP transceivers are available for your device. XFP transceivers are slightly larger than SFP transceivers. They support 10- Gigabit Ethernet only. Note: Use only Hirschmann SFP transceivers or XFP transceivers which are suitable for usage with the device. MACH104-20TX-F FAULT V.24...
  • Page 23: Device State

    1.7.1 Device state FAULT These LEDs provide information about conditions which affect the operation of the whole device. The following table applies to the stated device variants only:  MACH104-16TX-PoEP-R...  MACH104-16TX-PoEP+2X-R... Display Color Activity Meaning Supply — none Supply voltages 1 and 2 are too low. voltage green lights up...
  • Page 24: Port Status

    Display Color Activity Meaning ACA memory green Flashing Error in the memory operation operations alternately flashes Saves a configuration file from the storage synchronously medium ACA to the device. 2 × per period flashes Saves a configuration file from the device to synchronously the storage medium ACA.
  • Page 25: Management Interfaces

    Management interfaces 1.8.1 V.24 interface (external management) The V.24 interface is an RJ11 socket. The V.24 user interface is serial and allows you to connect the following devices directly:  External management station (VT100 terminal or PC with appropriate terminal emulation). With this management station, the Command Line Interface (CLI) is available to you.
  • Page 26: Signal Contact

    In the configuration, you specify how the device uses the signal contact. You find detailed information regarding possible applications and configuration of the signal contact in the software user documentation on the Hirschmann product pages (www.hirschmann.com). Installation MACH104-PoEP Release 08 01/2019...
  • Page 27: Installation

    “Scope of delivery” on page  Check the individual parts for transport damage. Installing an SFP transceiver (optional) Prerequisites: Exclusively use Hirschmann SFP transceivers. See “Accessories and order numbers” on page 47. Figure 4: Installing SFP transceivers: Installation sequence Installation MACH104-PoEP...
  • Page 28: Mach104-16Tx-Poep-E

    Proceed as follows:  Take the SFP transceiver out of the transport packaging (1).  Remove the protection cap from the SFP transceiver (2).  Push the SFP transceiver with the lock closed into the slot until it latches in (3). MACH104-16TX-PoEP-E..., MACH104-16TX-PoEP+2X-E...: Wiring and installation of the supply voltage...
  • Page 29: Wiring And Installing The Signal Contact

    Figure Function Protective grounding Minus terminal of the supply voltage Plus terminal of the supply voltage Table 12: 3-pin terminal block pin assignment  Remove the terminal connector from the device.  Connect the protective conductor with the clamp.  Connect the lines for the supply voltage to the + and - terminals. ...
  • Page 30: Installing The Device And Grounding

    Every time you connect the electrical conductors, make sure that the following requirements are met:  The electrical wires are voltage-free.  The connected voltage is limited by a current limitation device or a fuse. Observe the electrical threshold values for the signal contact. See “General technical data”...
  • Page 31: Mounting In A Switch Cabinet

    2.5.3 Mounting in a switch cabinet Note: For more information on sliding/mounting rails and how to install them, please contact your switch cabinet manufacturer. The devices are designed to be mounted in a 19" switch cabinet.  Ensure adequate ventilation. If necessary, install an additional fan in the switch cabinet to prevent the device from overheating.
  • Page 32: Mounting On The Wall

    You obtain the additional brackets as accessories. See “Accessories and order numbers” on page 47. 2.5.4 Mounting on the wall Note: In order to fix the device to a concrete wall choose screws with a thread major diameter of at least 5 mm. ...
  • Page 33: Operating The Device

    Operating the device WARNING ELECTRIC SHOCK Connect only a supply voltage that corresponds to the type plate of your device. Failure to follow these instructions can result in death, serious injury, or equipment damage. Note: Note the safety instructions in “Requirements for connecting electrical wires”...
  • Page 34: Making Basic Settings

     Input via the V.24 interface  Input via the HiView or Industrial HiVision application. You find further information about the applications HiView or Industrial HiVision on the Internet at the Hirschmann product pages: HiView http://www.hirschmann.com/en/QR/INET-HiView Industrial HiVision http://www.hirschmann.com/en/QR/INET-Industrial-HiVision ...
  • Page 35: Default Settings

    Default settings  The device looks for the IP address using DHCP  Management password: user, password: public (read only) admin, password: private (read and write)  V.24 data rate: 9600 Baud  Ring redundancy disabled  Ethernet ports: link status is not evaluated (signal contact) ...
  • Page 36: Maintenance And Service

    Maintenance and service  When designing this device, Hirschmann largely avoided using high-wear parts. The parts subject to wear and tear are dimensioned to last longer than the lifetime of the product when it is operated normally. Operate this device according to the specifications.
  • Page 37: Deinstallation

    Deinstallation Removing the device  Disconnect the data cables.  Disable the supply voltage.  Disconnect the supply voltage.  Remove the terminal connector from the device.  To detach the device from the switch cabinet or the wall, remove the screws from the brackets on the device.
  • Page 38: Technical Data

    Technical data General technical data Dimensions See “Dimension drawings” on page 40. Weight MACH104-16TX-PoEP... 10.14 lb (4.6 kg) MACH104-16TX-PoEP+2X... MACH104-16TX-PoEP-R... 11.46 lb (5.2 kg) MACH104-16TX-PoEP+2X-R... MACH104-16TX-PoEP-E... 9.7 lb (4.4 kg) MACH104-16TX-PoEP+2X-E... Supply voltage MACH104-16TX-PoEP... Rated voltage range MACH104-16TX-PoEP+2X... 100 V AC ... 240 V AC, 50 Hz ... 60 Hz MACH104-16TX-PoEP-R...
  • Page 39 PoE power Maximum number of Powered 8 × Powered Device (PD) class 4 (30 W) Devices (PDs) 16 × Powered Device (PD) class 0 (15.4 W) Power loss buffer MACH104-16TX-PoEP... > 20 ms MACH104-16TX-PoEP+2X... MACH104-16TX-PoEP-R... MACH104-16TX-PoEP+2X-R... MACH104-16TX-PoEP-E... > 10 ms MACH104-16TX-PoEP+2X-E...
  • Page 40: Dimension Drawings

    Dimension drawings 462,6 18.21 0.13 inch 19,3 19,3 0.76 17.48 0.76 EMC and immunity EMC interference immunity IEC/EN 61000-4-2 Electrostatic discharge Contact discharge 6 kV Air discharge 8 kV IEC/EN 61000-4-3 Electromagnetic field 80 MHz ... 3000 MHz max. 20 V/m IEC/EN 61000-4-4 Fast transients (burst) Power line...
  • Page 41 EMC interference immunity IEC/EN 61000-4-5 Voltage surges This applies to the following device variants only:  MACH104-16TX-PoEP-E...  MACH104-16TX-PoEP+2X-E... Power line, line / line 0.5 kV Power line, line / ground 1 kV Data line 1 kV This applies to the following device variants only: ...
  • Page 42: Network Range

    Network range Note: The line lengths specified for the transceivers apply for the respective fiber data (fiber attenuation and Bandwidth Length Product (BLP)/ Dispersion). 10/100/1000 Mbit/s twisted pair port Length of a twisted pair segment max. 328 ft (100 m) (for Cat5e cable) Table 13: Network range: 10/100/1000 Mbit/s twisted pair port Product code Mode...
  • Page 43 Product code Mode Wave length Fiber System Example for F/O Fiber /Dispersion M-SFP-... attenuation cable length attenuation -SX/LC... 850 nm 50/125 µm 0 dB ... 7.5 dB 0 mi ... 0.34 mi 3.0 dB/km 400 MHz×km (0 km ... 0.55 km) -SX/LC...
  • Page 44 Product code Mode Wave length Fiber System Example for F/O Fiber /Dispersion M-XFP-... attenuation cable length attenuation -SR/LC 850 nm 50/125 µm 0 dB ... 8.1 dB max. 0.041 mi 3.0 dB/km 400 MHz×km (0.066 km) -SR/LC 850 nm 50/125 µm 0 dB ...
  • Page 45 Product code Mode Wave length Wave length Fiber System Example for F/O Fiber Dispersion M-SFP-BIDI... attenuation cable length attenuation Type A LH/LC EEC LH 1490 nm 1590 nm 9/125 µm 5 dB ... 24 dB 14.29 mi ... 49.71 mi 0.25 dB/km 19 ps/(nm×km) (23 km ...
  • Page 46: Power Consumption/Power Output

    Power consumption/power output MACH104-PoEPdevice Maximum Maximum power consumption power output MACH104-16TX-PoEP... 330 W 300 Btu (IT)/h MACH104-16TX-PoEP+2X... MACH104-16TX-PoEP-R... 340 W 340 Btu (IT)/h MACH104-16TX-PoEP+2X-R... MACH104-16TX-PoEP-E... 300 W 200 Btu (IT)/h MACH104-16TX-PoEP+2X-E... Installation MACH104-PoEP Release 08 01/2019...
  • Page 47: Scope Of Delivery, Order Numbers And Accessories

    Scope of delivery, order numbers and accessories Scope of delivery  Device Scope of delivery MACH104-16TX-PoEP... Device MACH104-16TX-PoEP+2X... General safety instructions Casing feet, stick on 1 × 2-pin terminal block for signal contact 1 × Non-heating appliance cable (Euro model) 2 ×...
  • Page 48 943 042-001 M-SFP-LH/LC EEC 943 898-001 M-SFP-LH+/LC 943 049-001 M-SFP-LH+/LC EEC 942 119-001 SFP-GIG-LX/LC 942 196-001 SFP-GIG-LX/LC EEC 942 196-002 a. You find further information on certifications on the Internet at the Hirschmann product pages (www.hirschmann.com). Installation MACH104-PoEP Release 08 01/2019...
  • Page 49 SFP-FAST-MM/LC EEC 942 194-002 SFP-FAST-SM/LC 942 195-001 SFP-FAST-SM/LC EEC 942 195-002 a. You find further information on certifications on the Internet at the Hirschmann product pages (www.hirschmann.com). Bidirectional Gigabit Ethernet SFP transceiver Order number M-SFP-BIDI Type A LX/LC EEC 943 974-001...
  • Page 50 If your device has a shipping approval according to Germanischer Lloyd or DNV GL, you find the respective approval mark printed on the device label. You will find out whether your device has other shipping approvals on the Hirschmann website under www.hirschmann.com in the product information.
  • Page 51 Further support Technical questions For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You find the addresses of our partners on the Internet at http:// www.hirschmann.com. A list of local telephone numbers and email addresses for technical support...

Table of Contents