9
Function
1
2
BEKOMAT® 31U
3
Via the inlet line (1) the condensate flows into the
BEKOMAT
A capacitively functioning sensor (3) continuously
4
registers the filling level and relays a signal to the
electronic control as soon as the container is filled.
The pilot valve (4) is activated and the membrane (5)
opens the outlet line to discharge the condensate (6).
4
When the BEKOMAT
is reclosed tightly in time before unnecessary
5
compressed-air losses occur.
6
When applying supply voltage, the BEKOMAT
carries out a self-test.
The LED is lit orange for 1 second; subsequently,
the device changes over to the "ready-to-operate"
state and the LED is lit green.
Ready to operate, voltage is applied.
Test of the valve function (manual drainage):
Press and hold the push-button for approx. 2 s.
Do not use for permanent drainage.
®
31U and accumulates in the housing (2).
®
31U is empty, the outlet line
Function
®
31U
11
Need help?