Once your Zenith HydroTap G4 unit has been installed, Go to Install menu to
configure the system settings for your product.
1. - Filter Flush
Have a 10L bucket or similar container (not supplied) at the ready to hold
a quantity of water that will be ejected while the Filter Flush Mode is in
operation. Open the filter access door on the front of the HydroTap and the
filter cartridge will be exposed. Located to the rear RHS of the cartridge is a
flush line, approx 600mm long and the flush line stop cock. Place the valve
end of the flush line into the 10L bucket or container.
Note:
Run at least 10 Ltrs of
water through to flush the filter
of any excess black carbon
particles (this is normal). Once
the filter flush has finished,
press the Stop button to display
the main menu
ON
OPEN
Position
CLOSED
OFF
Position
The Zenith HydroTap allows the user to adjust the filter life and to edit the
filter usage. (See filter details on Page 20 ).
Page 14 of 28
Sub menu:
1 - Filter Flush
2 - Filter Reset
3 - Boiling Calibration
4 - Booster
5 - CO
6 - Lux Sensor Calibration
1.
Press the [MENU] button for main
menu.
2.
Press the [Install] button. Turn the
stop cock ON.
3.
Press the [Filter Flush] button.
4.
Press [Start] button to start filter
flush. Once the filter flush is
finished, Turn the stop cock OFF
first (to ensure the cock is properly
closed) then press [Stop] to end
filter flush mode.
5.
Press [<=] button for the previous
menu or press [Home] button to
return to the home screen.
6.
After initial installation, Turning
OFF the Filter Flush Mode puts the
HydroTap into calibration mode.
With subsequent filter changes, the
system reverts to the main menu.