YSP-900
K0/K1 (Panel key of main unit) [Remote control code: –]
A/D of the key fails to function properly when the standard
value is deviated by ±4%. In this case, check the constant
of partial pressure resistor, solder condition, etc. Refer to
table 2.
(Reference voltage: 3.3V=100%)
10. IF STATUS (Input function status)
Using the sub-menu, the status data is displayed one
after another in the hexadecimal notation.
During signal processing, the status before execution
of this menu is maintained.
* Numeric values in the figure example are for
reference.
IS1-3 (Internal status):
Indicates the status information of the microprocessor.
CS1-6:
Indicates channel status information of the input signal
(IEC60958).
BS1-7:
Indicates information of the bit stream included in the dts
and AAC signal.
DS1-2:
Register information of the DIR.
T11-3:
Operation information of the DSP IC (T1).
36
K0/K1  (本体パネルキー)
キーのA/Dは基準値から±4%を外れると、正常な動きをし
ません。下表2をご覧になり、各キーの分圧抵抗の定数、
ハンダ不良等の確認をしてください。
(基準電圧:3.3V=100%)
[Table 2 / 表2]
Display
K0
0+2
VOLUME +
VOLUME -
10±2
INPUT
100-2
NO KEY
NO KEY
10. IF STATUS
サブメニュー操作により、以下のステータス情報を順次
16進数で表示します。信号処理は、本メニュー実行前
の状態を維持します。
※ 図中の数値は参考例です。
IS1-3  (内部ステータス) :
マイコンのステータス情報を表示します。
5th byte
4th byte
3rd byte
2nd byte
1st byte
CS1-6:
入力信号のIEC60958チャンネルステータス情報を表示し
ます。
BS1-7:
dts信号およびAAC信号に含まれるビットストリームイン
フォメーション情報を表示します。
DS1-2:
DIRのレジスタ情報を表示します。
T11-3:
DSP IC (T1) の動作情報を表示します。
K1