Overload Protection; Overheat Protection; Overdischarge Protection - Makita XDT12 Instruction Manual

Hide thumbs Also See for XDT12:
Table of Contents

Advertisement

Available languages

Available languages

1
2
► 1. Red indicator 2. Button 3. Battery cartridge
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator on the
upper side of the button, it is not locked completely.
CAUTION:
Always install the battery cartridge
fully until the red indicator cannot be seen. If not,
it may accidentally fall out of the tool, causing injury to
you or someone around you.
CAUTION:
Do not install the battery cartridge
forcibly. If the cartridge does not slide in easily, it is
not being inserted correctly.
Tool / battery protection system
The tool is equipped with a tool/battery protection sys-
tem. This system automatically cuts off power to the
motor to extend tool and battery life. The tool will auto-
matically stop during operation if the tool or battery is
placed under one of the following conditions:

Overload protection

When the battery is operated in a manner that causes
it to draw an abnormally high current, the tool automat-
ically stops without any indication. In this situation, turn
the tool off and stop the application that caused the tool
to become overloaded. Then turn the tool on to restart.

Overheat protection

When the battery is overheated, the tool stops automat-
ically. In this situation, let the battery cool before turning
the tool on again.

Overdischarge protection

When the battery capacity is not enough, the tool stops
automatically. In this case, remove the battery from the
tool and charge the battery.
NOTE: Overload protection will work only with batter-
ies with star marking.
3
► 1. Star marking
Indicating the remaining battery
capacity
► 1. Battery indicator
When you pull the switch trigger, the LED display shows
the remaining battery capacity. The remaining battery
capacity is shown as the following table.
On
NOTE: When the LED display goes off, the tool is turned
off to save the battery power. To check the remaining
battery capacity, slightly pull the switch trigger.
NOTE: The LED display goes off approximately one
minute after releasing the switch trigger.
NOTE: When the LED display lights up and the tool
stops even with a recharged battery cartridge, cool down
the tool fully. If the status will not change, stop using and
have the tool repaired by a Makita local service center.
NOTE: When the tool is overheated, the light blinks for one
minute as shown in the table below, and then the LED display
goes off. In this case, cool down the tool before operating again.
5 ENGLISH
1
1
Battery indicator status
Off
Blinking
Remaining
battery
capacity
50% to 100%
20% to 50%
0% to 20%
Charge the
battery

Advertisement

Table of Contents
loading

Table of Contents