DC 12 V or AC 24 V power supply cable
Connect the power cord to the DC 12 V or the AC 24 V power supply.
The following table shows the connection distances when 2-core VVF (vinyl-
insulated vinyl sheath cables) are used. (Reference value)
Conductor diameter
Φ 1.0 mm (AWG 18)
Φ 1.6 mm (AWG 14)
Φ 2.0 mm (AWG 12)
If thin cables are used, the resistance of the cables will be high and a
Note
significant voltage drop will occur when the camera is at its maximum
power consumption. Either use a thick cable with low resistance or
place the power supply near to the camera and shorten the length of
the cable to restrict the voltage drop at the rated current of camera to
below 10 %. If voltage drop occurs during operation, the performance
will be unstable.
Do not connect the AC 24 V cable to commercial power supply. If it is
connected by mistake, the internal circuit may be damaged. Do not
use the camera and make sure to send it to the nearest JVC dealer for
inspection.
Do not connect DC 12 V and AC 24 V cables at the same time.
When connecting the DC 12 V cables, ensure that the polarities are
correct.
Color of the cables red: +12 V, black: GND
When using a DC 12 V power supply, ensure that the polarities of the
cable are correct.
The AC24 V power supply should conform to the following:
U-type: Class 2 only, E-type: Isolated power supply only
Maximum connection
distance: DC 12 V
50 m (160 ft)
140 m (450 ft)
220 m (720 ft)
Maximum connection
distance: AC 24 V
130 m (420 ft)
350 m (1100 ft)
550 m (1800 ft)