Transmit Power; Frequency Band 2.4 Ghz; Frequency Band 5 Ghz - Siemens SIMATIC NET Reference Manual

Industrial wireless lan performance data scalance w700 802.11ax
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Transmit power

3.1

Frequency band 2.4 GHz

The table below shows the maximum values that are possible for each sending antenna
connector.
• Tolerance ± 2 dBm
Protocol
802.11g
802.11n HT20
802.11n HT40
802.11ax HE20 MCS 0
802.11ax HE40 MCS 0
3.2

Frequency band 5 GHz

The table below shows the maximum values that are possible for each sending antenna
connector.
Tolerance ± 2 dBm
Max. conducted power
The value is the summed transmit power of all active antenna connections.
The calculation is made according to the following scheme:
• 1 antenna connection
max. transmit power = Max. conducted power
• 2 antenna connections
max. transmit power + 3 dBm = Max. conducted power
Performance data SCALANCE W700 802.11ax
Reference Manual, 04/2021, C79000-G8976-C620-01
Transmission
speed
2.412 GHz
6 Mbit/s
20
12 Mbit/s
20
54 Mbit/s
20
MCS 0
20
MCS 7
20
MCS 0
20
MCS 7
20
20
MCS 7
20
20
MCS 7
20
Max. transmit power (dBm)
2.442 GHz
20
20
20
20
20
20
20
20
20
20
20
3
Receiver sensi‐
tivity
(dBm)
2.472 GHz
2.442 GHz
20
-92
20
-89
20
-75
20
-90
20
-73
20
-88
20
-70
20
-90
20
-62
20
-88
20
-60
13