Item no. 10593-5-9970 · ENU · Change 212256 · Approved 2020-02-26 · Page 1 / 12
Operating instructions
·
·
·

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
DANGER
2
Indicates an imminently hazardous situation which will result in
2
death or serious injury if the specified actions are not taken.
2
Compliance with the instructions is imperative.
2
WARNING
2
Indicates a potentially hazardous situation which can result in
2
death or serious injury if the specified actions are not taken.
3
Exercise extreme caution while working.
CAUTION
4
Indicates a potentially hazardous situation which can result in
4
minor or moderate injury or damage to property if the specified
5
actions are not taken.
5
5
NOTE
6
A potentially harmful situation can occur and, if not avoided, can
6
lead to property damage.
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
7
authorized technical staff.
9
Only authorized specialists are permitted to install the device, to carry
10
out a test run and to perform work on the electrical installation.
10
10

1.3 Basic safety rules

10
The safety hazards associated with the device must be assessed again
10
following installation in the final product.
The locally applicable industrial safety regulations are always to be
11
observed when working on the device.
11
Keep the workplace clean and tidy. Untidiness in the work area
11
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.
·
·
·

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A4D500-AM01-03 and is the answer not in the manual?

Questions and answers

Summary of Contents for ebm-papst A4D500-AM01-03

  • Page 1: Table Of Contents

    Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions A4D500-AM01-03 WARNING 1.7 Emissions Live terminals and connections even with device WARNING switched off Depending on the installation and operating conditions, Electric shock the sound pressure level may exceed 70 dB(A). → Wait five minutes after disconnecting the voltage at all poles Risk of noise-induced hearing loss before opening the device.
  • Page 3: Intended Use

    Operating instructions A4D500-AM01-03 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions A4D500-AM01-03 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Airflow direction "V" Max. clearance for screw 12 mm Tightening torque 1.5 ± 0.2 Nm Cable diameter min. 6 mm, max. 12 mm, tightening torque 2 ± 0.3 Nm Item no.
  • Page 5: Nominal Data

    Operating instructions A4D500-AM01-03 3.2 Nominal data 09 Power consumption P / kW 0.63 09 Air flow q / m³/h 6045 Motor M4D110-GF 09 Pressure increase total p Phase 10 Speed (rpm) n / min 1370 Nominal voltage / VAC 11 Specific ratio 1.00...
  • Page 6: Mounting Data

    With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load CAUTION cycles. If you have special questions, consult ebm-papst for Cutting and crushing hazard when removing fan from support.
  • Page 7: Connection In Terminal Box

    Operating instructions A4D500-AM01-03 DANGER 4.2.3 Voltage control Electrical charge (>50 µC) between phase conductor and NOTE protective earth connection after switching off supply Current overshoots may occur if speed control is implemented with multiple devices connected in parallel. by transformers or electronic voltage regulators (e.g. phase Electric shock, risk of injury control).
  • Page 8 Operating instructions A4D500-AM01-03 4.3.3 Cable routing NOTE Lack of motor protection Water must be prevented from reaching the cable gland along the cable. Without motor protection, the motor can overheat and suffer NOTE damage. Damage caused by moisture penetration. → Connect the thermal overload protector installed in the Moisture can penetrate into the terminal box if water is winding.
  • Page 9: Connection Diagram

    Operating instructions A4D500-AM01-03 4.4 Connection diagram Δ Delta connection Star connection = V1 = blue = U1 = black = W1 = brown yellow green white 2x gray green/yellow Item no. 10593-5-9970 · ENU · Change 212256 · Approved 2020-02-26 · Page 9 / 12 ·...
  • Page 10: Opening Additional Cable Glands

    Operating instructions A4D500-AM01-03 4.5 Opening additional cable glands NOTE Damage to the device from vibration A second cable gland opening can be made in the terminal box. Bearing damage, shorter service life WARNING → Low-vibration operation of the fan must be ensured over the In the event of a fault, the cable gland is energized entire speed control range.
  • Page 11: Cleaning

    Deficient cooling Improve cooling Fastening the Visual inspection At least every Fasten In the event of further malfunctions, contact ebm-papst. cables 6 months Fastening the Visual inspection At least every Fasten protective earth 6 months terminal 5.1 Cleaning...
  • Page 12 ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 10593-5-9970 · ENU · Change 212256 · Approved 2020-02-26 · Page 12 / 12 · ·...