Download Print this page
Nahita 910/5 Manual

Nahita 910/5 Manual

Portable conductivity meter

Advertisement

Quick Links

ANNEX I: CE CERTIFICATE
AUXILAB S.L.
DECLARATION OF CONFORMITY
CONDUCTIVITY METER 910/5 of Auxilab, S.L for the
Directive of Machines (89/392/CEE modified) and the regulations
adopted for their transposition
NAME OF THE MANUFACTURER / IMPORTER:
AUXILAB, S.L.
ADDRESS:
Polígono Morea Norte, 8
31191 Beriáin (Navarra)
WE STATE THAT:
NAHITA CONDUCTIVITY METER 910/5
CODE 50910050
Are designed and manufactured according to:
Directive 89/392/CEE, including the modifications and national regulations that
transpose them.
Directive 89/336/CEE modified over electromagnetic compatibility.
And that the following harmonized rules have applied (or part of them):
UNE 292-1/-2/-2/A1,UNE-EN 1050, UNE-EN 614-1,UNE-EN 1037, UNE-EN
1088, UNE-EN 547, UNE-EN 953, UNE-EN 294, UNE-EN 418, UNE-EN 894-1, UNE-
EN 894-2, UNE-EN 954-1, UNE-EN 60204-1, UNE 61010-1/A2, UNE-EN61010-2-051.
BERIAIN 19th JUNE 2007
Signed by: ALFONSO AINCIBURU SANZ
DIRECTOR/MANAGER
Polígono Morea Norte, 8 31191 Beriain (Navarra) - Spain. Tel. 948 310 513 Fax 948 312 071
Internet: www.auxilab.es · Email: correo@auxilab.es
Page 32
Instruction manual 50910050
ENGLISH
Version 1 June-07
CONDUCTÍMETRO DE CAMPO
PORTABLE CONDUCTIVITY METER
MODELO / MODEL 910/5
Este manual es parte inseparable del aparato por lo que debe estar
disponible a todos los usuarios del equipo. Le recomendamos leer
atentamente el presente manual y seguir rigurosamente los proce-
dimientos de uso para obtener las máximas prestaciones y una
mayor duración del mismo.
This manual should be available for all users of these equipments. To get
the best results and a higher duration of this equipment it is advisable to
read carefully this manual and follow the processes of use.
Revisión 1 Junio-2007
Manual de instrucciones 50910050
Pág. 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 910/5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nahita 910/5

  • Page 1 ANNEX I: CE CERTIFICATE AUXILAB S.L. DECLARATION OF CONFORMITY MODELO / MODEL 910/5 CONDUCTIVITY METER 910/5 of Auxilab, S.L for the Directive of Machines (89/392/CEE modified) and the regulations adopted for their transposition NAME OF THE MANUFACTURER / IMPORTER: AUXILAB, S.L.
  • Page 2 Gracias por haber adquirido este equipo. Deseamos sinceramente que disfrute del con- Accesories ductímetro de campo Nahita 910/5. Le recomendamos que cuide el equipo conforme a lo Conductivity meter Nahita 910/5 is supplied without a conductivity cell. The following expuesto en este manual.
  • Page 3 Note: The equipment also presents a low battery alert. When the batteries are lack of El conductímetro Nahita 910/5 resulta ideal para trabajos de campo en el análisis de energy, a sign of low battery will be displayed to remind the user to change the batteries.
  • Page 4 Press MODE/MEAS (1.3) to return to the measuring mode. 4. Data printing 3. ESPECIFICACIONES TÉCNICAS The results obtained with the conductivity meter 910/5 can be printed with a TP-16 prin- Referencia 50910050 ter. For this purpose, connect the conductivity meter with the printer through the interfa- ce RS232.
  • Page 5 0.5 Kg Peso 1. Data saving Nahita conductivity 910/5 can store up to 250 readings of each measuring mode. For this purpose, at any measuring mode press /SAVE (1.6) and the result will be automati- 4. INSTALACIÓN / PUESTA EN MARCHA cally saved.
  • Page 6 80000 52168 48384 79688 Nahita 910/5 puede ser utilizado con células de conductividad de diferente valor de cons- *442: 40% Na , 40% NaHCO , 20% NaCl tante (ver Accesorios) permitiendo ajustar el valor de la constante de la célula de conduc- tividad utilizada en cada momento.
  • Page 7 Selección del modo de trabajo Submerge the conductivity cell in the standard solution. Control the temperature of the standard solution to be (25.0±0.1) ºC, (20.0±0.1) ºC, (18.0±0.1) ºC or (15.0±0.1) ºC. El conductímetro Nahita 910/5 le permite la determinación de: μ a. Conductividad ( S/cm) Select the level of the constant value (0.01, 0.1, 1.0, 5.0 or 10.0) (see Parameter adjus-...
  • Page 8 2. TDS conversion factor adjustment 22.5 ºC Nahita conductivity meter 910/5 takes by default a value of 0.50 for the TDS conversion factor. The user can adjust this value within a range from 0.40 to 1.00. For this purpose, proceed as follows: In the TDS measuring mode press MODE/MEAS (1.3).
  • Page 9 2. Ajuste del factor de conversión TDS El conductímetro Nahita 910/5, por defecto toma un valor de 0.50 para el factor de con- versión TDS. El equipo permite ajustar este valor en un rango entre 0.40 y 1.00. Para ello, 4.50...
  • Page 10 74.2650 trument will be ready to operate. 7.4365 Selection of the measuring mode 0.01 0.7440 Nahita conductivity meter 910/5 can perform determinations of: 0.001 Disolver 100 mL de solución 0.01 mol/L en 1 L μ a. Conductivity ( S/cm) Conecte la célula de conductividad al equipo y desconecte la sonda de temperatura; de b.
  • Page 11 Selection of the conductivity cell 12880 7447 7230 11367 To adapt to any application, Nahita conductivity meter 910/5 can be used with conduc- tivity cells of different constant value (see Accessories) allowing to adjust the constant 15000 8759 8532 13455 value of the cell to be used at any moment.
  • Page 12 CASTELLANO ENGLISH Calibre la constante de la célula de conductividad según el apartado Calibración de la ± 1.5 % Precision (± 1 digit) célula de conductividad. Total dissolved solids (TDS) Seleccione el modo de medida TDS Limpie la célula de conductividad con agua destilada. Range 0.00-10.00 mg/L;...
  • Page 13 Otras funciones 1.3 MODE/MEAS 1. Guardar datos 1.4 ENTER/PRINT El conductímetro Nahita 910/5 puede almacenar hasta 250 lecturas de cada modo de /C/T/S medida en su memoria. Para ello, en el modo de medida pulse /SAVE (1.6) y el dato /SAVE se guardará...
  • Page 14 CASTELLANO ENGLISH 4. Imprimir datos INDEX OF LANGUAGES Los datos obtenidos con el conductímetro 910/5 pueden ser impresos a través de una Spanish 2-19 impresora de etiquetas. Para ello, conecte el conductímetro con la impresora a través de la interfaz RS232.
  • Page 15 ENGLISH CASTELLANO Thank you for choosing this equipment. We sincerely wish that you enjoy your Nahita gúrese de que se han retirado las pilas y protéjalo del polvo (evitando así posibles acci- portable conductivity meter 910/5. We highly recommend looking after this equipment dentes y prolongando la vida útil del equipo).
  • Page 16 DECLARACIÓN CE DE CONFORMIDAD Mantenimiento de la célula de conductividad. Enjuague la célula de conductividad CONDUCTÍMETRO 910/5 de Auxilab,S.L a la Directiva con agua limpia después de las mediciones. Si precisa una limpieza mas a fondo, limpie de Máquinas (89/392/CEE modificada) y a las reglamentaciones la célula con un paño o un detergente no abrasivo.