Inserting a sample using a sample catcher

Ejecting and removing a sample using a sample catcher

Cryogenic Systems Operation
Turn on the eject air from VnmrJ or VNMR using the
1
eject button or eject command.
2
Remove the current turbine and sample if one is present.
3
Disable the sample catcher by sliding the switch to the
right so that the catcher lever no longer extends into the
bore of the sample catcher.
4
Place turbine with sample atop the sample catcher, the
turbine and sample will float on the eject air stream.
Insert the turbine and sample into the probe from VnmrJ
5
or VNMR using the insert button or insert command.
6
Enable the sample catcher by sliding the switch to the
left and extending the catcher lever into the bore of the
sample catcher.
Turn on the eject air from VnmrJ or VNMR using the
1
eject button or eject command.
Remove the turbine and sample held in place by the
2
sample catcher release lever.
Turn off the eject air or insert a new sample.