A. If installing appliance on the floor level,
you must maintain the minimum distance
of 14" to combustibles (see Figure 8).
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
This appliance is factory
preset for propane/LP gas.
No changes are required for
connecting to propane/LP . Only
a qualified installer or service
technician can perform gas selec-
tion and connecting to gas supply.
CAUTION: Two gas line in-
stallations at the same time are
prohibited. The access plate
to the simple switching means
shall not be opened while the
heater is in operation.
CAUTION: To avoid gas
leakage at the inlet of regulator,
a qualified installer or service
technician must use supplied
hex plug with sealant.
WARNING: Do not attempt to
access or change the setting of
the fuel selection means.
Access to and adjustment of the fuel selection
means must only be performed by a qualified
service person when connecting this appliance to
a specified fuel supply at the time of installation.
200015-01B
INSTALLATION
FLOOR CLEARANCES
Combustible
Material
14"
Min.
Noncombustible Material
GAS SELECTION
www.usaprocom.com
B. If combustible materials are less than 14"
to the fireplace, you must install appliance
at least 5" above the combustible flooring
(see Figure 9).
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Change of the selector setting to other than
the fuel type specified at the time of installa-
tion could damage this appliance and render
it inoperable.
The installer shall replace the access cover
before completing the installation and operat-
ing this appliance.
For changing from propane to
natural gas supply:
1. Remove 2 screws from cover plate located
on left side of heater (see Figure 10).
2. For NATURAL GAS, press in knob using a
flat screwdriver with a blade with thickness
of a quarter and turn knob clockwise
until the knob locks into the NG position
(see Figure 10). Fuel selection device
must be locked in the NG position. Do not
operate heater between locked positions!
3. Replace cover over fuel selection device
and reinstall screws.
Hex Plug
LP
NG
Gas
Connection
Fitting
Figure 10 - Settings for Natural Gas
Selection
Hearth
Combustible
Material
5"
Min.
Fuel Selector Knob
NG
LP
Left Side of Heater
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crheb30rt

Table of Contents