Daikin RXG20L2V1B Installation Manual

Daikin RXG20L2V1B Installation Manual

R410a split series
Hide thumbs Also See for RXG20L2V1B:

Advertisement

Quick Links

INSTALLATION
MANUAL
R410A Split Series
Models
RXG20L2V1B
RXG25L2V1B
RXG35L2V1B
Installationsanleitung
Split-Baureihe R410A
Manuel d'installation
R410A Split-systeem
Manual de instalación
Manuale d'installazione
Serie Multiambienti R410A
Εγχειρίδιο εγκατάστασης
∆ιαιρούμενης σειράς R410A
Manual de Instalação
Руководство по монтажу
Серия R410A с раздельной установкой
Installation manual
R410A Split series
Série split R410A
Montagehandleiding
Serie Split R410A
Série split R410A
Montaj kılavuzları
R410A Split serisi
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
Portugues
Русский
Türkçe

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RXG20L2V1B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin RXG20L2V1B

  • Page 1 Installationsanleitung Deutsch Split-Baureihe R410A Manuel d’installation Français Série split R410A Montagehandleiding Nederlands R410A Split-systeem Models Manual de instalación RXG20L2V1B Español Serie Split R410A RXG25L2V1B Manuale d’installazione RXG35L2V1B Italiano Serie Multiambienti R410A Εγχειρίδιο εγκατάστασης Ελληνικά ∆ιαιρούμενης σειράς R410A Manual de Instalação Portugues Série split R410A...
  • Page 3 3P290872-15...
  • Page 4: Safety Precautions

    Safety Precautions • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. • Meaning of WARNING and CAUTION notices WARNING ..Failure to follow these instructions properly may result in personal injury or loss of life. CAUTION ..
  • Page 5: Precautions For Selecting The Location

    • Take adequate steps to prevent the outdoor unit being used as a shelter by small animals. Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean. •...
  • Page 6: Outdoor Unit Installation Drawings

    Outdoor Unit Installation Drawings Max. allowable piping length Min. allowable piping 1.5m length Wrap the insulation pipe with Max. allowable piping the finishing tape from bottom height to top. Additional refrigerant required for refrigerant 20g/m pipe exceeding 10m in length. Gas pipe O.D.
  • Page 7: Precautions On Installation

    Installation Guidelines • Where a wall or other obstacle is in the path of outdoor unit’s inlet or outlet airflow, follow the installation guidelines below. • For any of the following installation patterns, the wall height on the outlet side should be 1200mm or less. Wall facing one side Wall facing two sides More than 50...
  • Page 8 Outdoor Unit Installation Flaring the pipe end 1) Cut the pipe end with a pipe cutter. (Cut exactly at right angles.) Remove burrs. 2) Remove burrs with the cut surface facing downward so that the chips do not enter the pipe. Flaring Set exactly at the position shown below.
  • Page 9 Outdoor Unit Installation Evacuating the air with a vacuum pump and checking gas leakage WARNING • Do not mix any substance other than the specified refrigerant (R410A) into the refrigeration cycle. • When refrigerant gas leaks occur, ventilate the room as soon and as much as possible. •...
  • Page 10 Outdoor Unit Installation Refilling the refrigerant Check the type of refrigerant to be used on the machine nameplate. Precautions when adding R410A Fill from the gas pipe in liquid form. It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, preventing normal operation. 1) Before filling, check whether the cylinder has a siphon attached or not.
  • Page 11: Standby Electricity Saving

    Standby Electricity Saving The standby electricity saving function turns off power supply to the outdoor unit and sets the indoor unit into standby electricity saving mode, thus reducing the power consumption of the air conditioner. CAUTION • The standby electricity saving function cannot be used for models other than the specified ones. ...
  • Page 12: Pump Down Operation

    Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve cap from liquid stop valve and gas stop valve. Hexagonal wrench Liquid 2) Carry out forced cooling operation. stop valve Close 3) After 5 to 10 minutes, close the liquid stop valve with a hexagonal wrench.
  • Page 13 Wiring WARNING • Do not use tapped wires, extension cords, or starburst connections, as they may cause overheating, electrical shock, or fire. • Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the terminal block.) Doing so may cause electric shock or fire.
  • Page 14 Wiring Wiring diagram Terminal strip Field wiring Connector Relay connector Connection Terminal Black Orange Blue Brown White Green Yellow Notes Refer to the nameplate of the unit for power requirements. TO INDOOR UNIT To indoor unit POWER SUPPLY Power supply IN CASE OF COOLING ONLY TYPE In case of cooling only type OUTDOOR...
  • Page 15: Trial Operation And Testing

    Trial Operation and Testing Trial operation and testing 1-1 Measure the supply voltage and make sure that it falls in the specified range. 1-2 Trial operation should be carried out in either cooling or heating mode. • In cooling mode, select the lowest programmable temperature; in heating mode, select the highest programmable temperature.
  • Page 16 3P358184-1E 2015.10...

This manual is also suitable for:

Rxg25l2v1bRxg35l2v1b

Table of Contents