Do not skip this instruction manual. Read the instruction manual carefully before using the equipment. If failed in doing so it may cause serious injury or Death. Advanced Safety Solutions Inc. 304, County Park Road, Avella, Pa 15312. This manual must be read and understood in its entirety and used as part of fall protection training program as required by OSHA or any state regularity agency.
Page 3
2.0 MATERIAL: All Advance Safety Lanyards have been manufactured by using Polyester/Nylon/Aramid/Steel. The Shock absorbing lanyards which have been tested for 6 foot free fall have different colour tracer for identication. As against the above, the lanyards which are tested for 12 foot free fall have different colour tracer for easy distinction. Refer g.2 for applications. A.
E. Physical and Environmental Hazards: Use of this equipment in areas Calculating Total Fall Distances: with physical or environmental hazards may require additional Total Fall Clearance below worker is calculated from Anchorage Connection. Free Fall Distance precautions to reduce the possibility of injury to the user or damage to + Energy Absorber Deceleration Distance + the equipment.
Figure 6 - Anchorages NOTE: L arge throat opening snap hooks should not be connected to standard size D-rings or similar objects which will result in a load on the gate if the hook or D-ring twists or rotates. Large throat snap hooks are designed for use on xed structural elements such as rebar or cross members that are not shaped in a way that can capture the gate of the hook.
Page 6
Figure 7 - Hook Operation 4.1 Before Each Use of this equipment, carefully inspect it to assure that it is in STEP 1 STEP 1 serviceable condition. Check for worn or damaged parts. Ensure that all Rotate Clockwise Depress locking hardware is present and secure.
Page 7
IMPORTANT: If this equipment has been subjected to forces resulting from the arrest of a fall, it must be immediately removed from service and destroyed or returned to Advance Safety for possible repair. See section 6.2. for inspe c t i n g the equipment. Extreme working conditions (harsh environment, prolonged use, etc.) may require increasing the frequency of inspections.
Page 8
7.5 Inspection & maintenance log. YR J F M A M J J A S O N D USER MUST INSPECT BEFORE EACH USE. Competent Person to inspect and initial at least every 6 months. Date of First Use (please complete) __________________ 8.0 LABELING &...
Page 9
8.4 Y Lanyard (6ft. & 12ft.) free fall carry a dynamic hip test failure warning label on both connecting ends instructing users to safely store the unused leg of lanyard. Warning: User must ensure that unused Leg of the Y lanyard is safely stored and it does not cause obstruction. 9.0 MATERIAL OF CONSTRUCTION OF ENERGY ABSORBING LANYARD : 9.1 Lanyard is made of high tenacity Polyester yarn/Nylon/Steel/Aramid.
Page 11
PERIODIC EXAMINATION AND REPAIR HISTORY Date Reason for entry Defects noted, repairs Name and signature Periodic examination (periodic examination carried out and other of competent user next due date or repair) relevant information Advanced Safety Solutions Inc. 304, County Park Road, Avella, Pa 15312.
Need help?
Do you have a question about the Ansi 9206C-LE and is the answer not in the manual?
Questions and answers