Page 1
HIGH PRESSURE CLEANER MODEL NO: SCWD082 (HP30250DE) SCWD084 (HP23350DE) MADE IN AUSTRALIA SPITWATER AUSTRALIA PTY LTD 953 METRY STREET NORTH ALBURY NSW 2640 AUSTRALIA WARNING: Read and understand this instruction manual before operating this unit and retain for future reference.
Page 2
SPARE PARTS, ACCESSORIES AND AFTER SALES SERVICE Spitwater has an extensive range of spare parts and accessories to suit all your cleaning needs. For spare parts, accessories and service please contact 1800 SPITWATER (1800 774 892) and to view Spitwater's extensive range of high pressure cleaners online visit www.spitwater.com.au...
TECHNICAL DATA MODEL HP30250DE HP23350DE PRODUCT SCWD082 SCWD084 #N/A UNIT PERFORMANCE FLOW RATE PRESSURE #N/A PRESSURE #N/A NOZZLE #N/A WATER INLET PRESSURE MAX #N/A TEMP MAX #N/A °C ENGINE ENGINE MODEL KUBOTA D902 KUBOTA D902 TYPE DIESEL DIESEL SPEED 3570...
DESCRIPTION OF SYMBOLS The following symbols are used throughout this instruction booklet in order to mark important paragraphs or sections that require particular attention. Their meaning is listed next to them for your attention. The following symbols are used on the unit in order to warn user of potential injury if not cautious. Their meaning is listed next to them for your attention.
Page 5
SAFETY LABELS, UNIT COMPONENTS FEATURES & CONTROLS • Always pay attention to the safety instructions provided on each label. Do not alter or remove safety labels PRESSURE HIGH / LOW ISOLATOR (SCW082 ONLY) LATCH SERIAL LABEL CONTROL MODULE KEYSWITCH HOUR METER TRIGGER E-STOP PRESSURE...
CONTROLLER GUIDE ICON DESCRIPTION PRE HEAT AUXILIARY ALARM LOW OIL PRESSURE ENGINE-HIGH TEMPERATURE BATTERY UNDER VOLTAGE / BATTERY OVER VOLTAGE OVER SPEED STOP / RESET: Turning the keyswitch to this position places the controller into its STOP/RESET mode. This will clear any alarm unless the alarm condition is still present. RUN: Moving the keyswitch into this position.
GENERAL SAFETY PRECAUTIONS 1. OBSERVE SAFETY INSTRUCTIONS • Make sure you have read and understood the whole instruction manual before installing, operating or carrying out any maintenance on this unit. • Warnings and data plates on the unit provide important directions and information on the safe use of the unit.
4. EXHAUST & FLUE GASES • Do not use combustion engine powered machines indoors unless adequate ventilation is assessed by national labor authorities. • Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death.
OPERATIONAL SAFETY PRECAUTIONS All health and safety regulations applicable to general safe work practices, as well as safe operation of equipment, as well as any specific standard for safe operation of high pressure cleaners according to local regulations must be followed. When operating this unit, 1.
Never exceed the maximum working temperature and pressure as indicated on the unit data plate and in this manual. • Only use this unit with cleaning chemicals recommended by Spitwater. The use of other cleaning agents or chemicals may adversely affect the safety of the unit. •...
5. When not in use the unit must be stored in a dry building where there is no possibility for the temperature to be at or below 0°C. If necessary to store the unit at or below 0°C contact your authorized Spitwater service agent for advice.
Page 12
Visually check for any damage, leaks or other issues. If any problem is found, contact your Spitwater agent immediately. 3. Identify the unit from the information on the serial label affixed to the unit.
Page 13
Add nozzle shield after nozzle assembly. Refer diagram below. SCWD082 11. LANCE, TRIGGER GUN & HIGH PRESSURE HOSE ASSEMBLY (SCWD082 ONLY) • Connect the lance to the spray gun by an in-built quick release coupling.
Page 14
12. NOZZLE ASSEMBLY (SCWD084 ONLY) SCWD084 Connect the High pressure nozzle to the lance. Do not over tighten. 13. TRIGGER GUN & HIGH PRESSURE HOSE ASSEMBLY (SCWD084 ONLY) • Connect the high pressure hose fittings to the spray gun using a 3/8” nipple from the accessories bag. Do not over tighten.
Contact your Spitwater agent for advice and /or supply. • Make sure the water supply temperature and pressure meet the values specified in the technical data, then turn the water supply on. Visually check for leaks and contact your Spitwater service agent if found. •...
Page 16
16. Remove the DIESEL tank cap and fill the diesel tank with clean filtered diesel. ONLY USE CLEAN DIESEL IN THIS UNIT, as using any other fuel will create a risk of explosion and damage to the unit.
CHECK LIST” in the SERVICE / CARE section as a guide. If the unit is damaged or faulty in anyways, DO NOT use it and immediately contact your authorized Spitwater service agent for advice. TO START 1. Always wear appropriate Personal Protective Equipment.
USING CLEANING AGENT SCWD082 ONLY 1. Fill the detergent tank with cleaning solution. Only use a cleaning detergent approved by the manufacturer and do not use any circumstance acid or corrosive products (contact an authorized service agent or the manufacturer if in doubt).
Page 19
1. Close the chemical injector by turning it clockwise running the water through it and dropping the until it stops. (SCWD082 ONLY) detergent line into a container of clean water. 2. Turn the key switch to STOP position (Position O).
2. Carry out all regular maintenance and Spitwater recommends that all maintenance is inspections as listed in this manual using carried out by an authorized Spitwater service original Spitwater parts where required. agent using original Spitwater spare parts. 3. Always make sure before carrying out any...
● Dark fumes = abnormal condition, unit needs attention. ● Clear fumes = ideal condition to run the unit. Unusual noise from unit. STOP operting the unit, Unit is fit, proceed task Contact Spitwater service agent immediately Contact Spitwater service Do It Yourself, agent / Qualified person for...
Page 22
USAGE VS SERVICE FREQUENCY TABLE-A: Usage vs Service Frequency For more information on service intervals of the Kubota diesel engine, refer manual. Time interval for checks and replacement listed above are for units subjected to normal operating conditions. Should the unit be subjected to abnormal conditions (eg heavy use, dirty water, extreme temperatures or conditions etc) times should be reduced accordingly.
OIL CHECK POINTS PUMP OIL ENGINE OIL CHECK CHECK Ensure the unit is on a flat surface. Ensure the unit is on a flat surface, and check the amount and condition Check the oil level in the pump using of the oil with an oil plug. the dipstick or the sight glass on the back / side of the pump.
TROUBLESHOOTING GUIDE If the fault cannot be identified or corrected using the below list (or remedy suggests contacting Spitwater service agent) stop using the unit immediately and contact your authorized Spitwater service agent to rectify. TROUBLESHOOTING GUIDE FAULT CAUSE REMEDY...
Need help?
Do you have a question about the SCWD082 and is the answer not in the manual?