Datafill Sequence And Implications; Datafill; Table 14 Field Descriptions For Table Iphost For Eiu Datafill - Nortel DMS-100 User Manual

Nortel ethernet interface unit user guide
Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Datafill sequence and implications
The following tables must be datafilled before table IPHOST:
Before entering data into table IPROUTER, Nortel Networks recommends
placing the corresponding EIUs referred to in the datafill in the OFFL state..
Datafill
Table 14 lists the fields and value ranges used to datafill an EIU in table
IPHOST.
While table 14 provides all the information you need to datafill for EIUs,
complete information on table IPHOST is in DMS-100 Translations Guide,
297-xxxx-350.

Table 14 Field descriptions for table IPHOST for EIU datafill

Field
Subfield or
refinement
INDEX
NODEIDX
(Sheet 1 of 2)
IPNETWRK
Inventory tables for nodes that are datafilled in field nodename in table
IPHOST
Note: In the assignment of IP addresses, the LAN side and the workstation
need to be on different subnets from the DMS peripheral module (PM).
Entry
refer to subfield
0 to 63
Explana tion and action
Index
This field consists of subfield
NODEIDX.
Node index
Enter the node index number.
DMS-100 Family EIU User Guide TELECOM12