2.
SYSTEM CONFIGURATION
[When the AnS dedicated extension base is used]
An example when the 32-point module is installed to
each slot is shown.
System configuration
Maximum number of
extension stages
Maximum number of
I/O modules
Maximum number of
I/O points
Main base unit model
name
Extension base unit
model name
Extension cable
model name
(1) Only one A
(2) When the extension base A1S52B(S1), A1S55B(S1), A58B(S1) or A52B, A55B, A58B are used, the 5VDC
power is supplied from the power supply module of the main base unit. Before use, refer to Section 6.1.3
Notes
and examine if it can be used.
(3) Limit the length of extension cable to 6m (236inch) or shorter.
(4) When using the extension cable, do not tie it with the main circuit cables, which has high voltage, large
current, or install them close to each other.
(1) Assign I/O numbers to the main base unit first, then to the extension base unit.
(2) Assign I/O numbers as if both main base unit and extension base unit have 8 slots each. When the
A1S32B/A1S33B/A1S35B for 2/3/5 slots are used as the main base unit, add 6/5/3 slots (96 points/80
points/48 points) and assign the extension base unit I/O numbers.
I/O number
(3) 16 points are assigned to an empty slot.
assignment
(4) When an extension base for A
(When I/O assignment is
not performed)
the number of skipped stages, 16 points/slot are assigned to all of skipped stages 8 slots, and thus it does
not work.
(5) Items (2) to (3) can be changed by the I/O assignment.
(Refer to the ACPU/QCPU-A (A Mode) Programming Manual (Fundamentals).)
(b) A2USCPU, A2ASCPU system
3rd extension stage
A1S65B(S1), A1S68B(S1), A1S52B(S1),
A1S55B(S1), A1S58B(S1)
A1SC03B, A1SC07B, A1SC12B, A1SC30B,
A1SC01B (right-side installation), A1SC60B
N, A
A extension base can be used. (The second extension module cannot be used.)
[When the A
An example when the 32-point module is installed to
each slot is shown.
1st extension
stage
UNIT
1
2
3
4
5
6
7
16 modules
512 points
A1S32B, A1S33B, A1S35B, A1S38B
A62B, A65B, A68B, A52B, A55B, A58B
A1SC05NB, A1SC07NB, A1SC30NB, A1SC50NB
N or A
A is used, be sure to set to a single extension level. If it is set to
2 - 29
N, A
A extension base is used]
Main base
Slot No.
unit
(A1S38B)
0
1
2
3
4
00
20
40
60
80
A0
to
to
to
to
to
to
1F
3F
5F
7F
9F
BF
Extension cable
Slot No.
8
9 10 11 12 13 14 15
1
100 120
140
160
180
2
3
4
to
to
to
to
to
5
6
7
11F
13F
15F
17F
19F
Extension base unit (for A
1st extension stage
5
6
7
E0
C0
to
to
DF
FF
1A0
1C0
1E0
to
to
to
1BF
1DF
1FF
N, A A)