11. Safety devices

Type of
protection
Circuit
Current fuse
protection
(Main PCB)
Fan motor
Thermal protection program
protection
Thermal protection program
(Discharge temp.)
Compressor
Thermal protection program
protection
(Compressor temp.)
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY
mode)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
Activate
Reset
- 50 -
Model
AOHG30KMTA
AOHG36KMTA
250 V, 30 A
250 V, 3.15 A
250 V, 10 A × 2
122 ±9 °C
Fan motor stop
107—126 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
108 °C
Compressor stop
80 °C or less
Compressor restart
-20 °C
Compressor stop
-15 °C
Compressor restart