Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 1 of 16 by SR Instruments, Inc. SRV947R REMOTE DISPLAY PLATFORM SCALE Operating and Service Manual SInstruments, Inc. 600 Young Street, Tonawanda, NY 14150...
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 2 of 16 TABLE OF CONTENTS TABLE OF FIGURES ........................2 PACKING CHECKLIST – MODEL SRV947R ................3 ASSEMBLY............................3 SYSTEM DESCRIPTION AND INTENDED USE ...............4 MAINTENANCE AND CLEANING ....................5 STORAGE AND TRANSPORTATION ..................5 SPECIFICATIONS...........................6...
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 4 of 16 SYSTEM DESCRIPTION AND INTENDED USE SYSTEM DESCRIPTION The SRV947R Portable Platform Scale is a low profile design, 2 in. height, which allows the animal easy step access.
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 5 of 16 MAINTENANCE and CLEANING The SRV947R Portable Platform Scale is made with a polyurea-coated aluminum platform. Exercise caution when cleaning the display window as it is made of a clear plastic and can be scratched by abrasive cleaners.
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 6 of 16 SPECIFICATIONS 400 lb / 182 kg MAXIMUM WEIGHT CAPACITY 24 in x 48 in x 2 in PLATFORM SIZE (61 cm x 122 cm x 5 cm) DISPLAY TYPE 1.0”...
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 7 of 16 BUTTON FUNCTIONS Figure 1: SRV947R Button Label The “ZERO/WEIGH” button is used to clear the Recall memory and start a new ZERO weighing cycle.
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 8 of 16 BASIC SYSTEM OPERATION TURNING SYSTEM ON Make sure the scale is free and clear of any obstructions and all six feet are touching a level surface.
Page 9 of 16 THEORY OF OPERATION SR Instruments patient weighing systems are digital scales. Strain-gauge force cells convert the force of an applied weight into an analog signal. This signal is amplified by an operational amplifier and converted to a digital signal by analog to digital converter. The digital signal is transferred to a micro- controller where it is filtered, converted to appropriate units, and displayed on a liquid crystal display.
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 10 of 16 CALIBRATION IMPORTANT CALIBRATION CHECK Qualified service personnel only should perform this procedure. Load cells have no user serviceable components and should not be tampered with for any reason.
Page 11
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 11 of 16 INITIAL SYSTEM SETUP When initially set up, calibration is factory set and re-calibration is not needed. The Local Gravitational Acceleration may have to be re-set for the current geographical location for improved accuracy.
Page 12
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 12 of 16 Set the Gravitational Acceleration (Optional) NOTE: Setting the local gravitational acceleration, “gLOC”, will not affect the calibration. The local gravitational acceleration, “gLOC”, will become the calibrated gravitational acceleration, “gCAL”...
Page 13
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 13 of 16 Set the Half-Scale value NOTE: The Half-Scale value is used only with the three-point calibration. It is a value between zero and the Full Scale values. It is usually close to half of the Full Scale value. a) Select the Half-Scale from the CAL menu by pressing the Left Button when the display shows “HALF”.
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 14 of 16 TROUBLESHOOTING SYMPTOM REASON/CORRECTIVE ACTION Weight reading is much lower than Check that the platform is clean underneath, stand on expected. each of the four corners to see if one corner is not weighing correctly.
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 15 of 16 DISPLAY MOUNTING TEMPLATE Determine installation location for scale and display, keeping in mind the display cable length is six (6) feet and the display power cord length is four (4) feet. The display may lay flat on a desk or end table.
Page 16
Model SRV947R 24 X 48 Remote Display Platform Operating and Service Manual Part No. MAN947R _190624 Page 16 of 16 By SInstruments, Inc. Precision & Technology in Perfect Balance SInstruments, Inc. 600 Young Street, Tonawanda, NY 14150 Tel: 716-693-5977 Fax: 716-693-5854 URL: www.srscales.com Copyright 2019 SInstruments, Inc.
Need help?
Do you have a question about the SRScales SRV947R and is the answer not in the manual?
Questions and answers