MOLDED-CASE CIRCUIT-BREAKERS
EARTH-LEAKAGE CIRCUIT-BREAKERS
INSTRUCTION MANUAL FOR V TYPE OPERATING HANDLE
Breaker type applicable
Breaker type applicable
Dimensions (mm)
Type
name
MCCB
ELCB
A
B
pole
pole
V-1UV
NF125-UV
2
3
4
39
30
・
・
V-1UVE
V-2UV
NF250-UV
2
3
4
41
35 201
・
・
V-2UVE
Note1
Please confirm whether the delivered product is the same as the order's one.
2
Please contact us for other models except above table.
3
(a) and (b) of the securing screw is shown the location for Drilling Plan.
Outline
Dimensions
&
Front plate
Center of
breaker
G
Plate
Trip
button
thickness
16
1.2
3.2
F
〜
A
61
48
Trip
button
90
54
125
2
±
It cannot be used when the IEC 35mm rail mounting.
The marks used respectively mean the following.
●
CAUTION
Wrong handling can cause dangerous situation in whichi possibility of fatal
accidents or serious injuries assumed.
This means prohibition.
Never ignore this indication.
1. Be sure to follow for the performance of IP65
CAUTION
1
Please the door of the door when the space is generated by the distortion etc.of the door.
(
)
2
Please tighten the screw of the handle unit surely by a regulated torque.
(
)
3
Please front plate cutout according to front plate cutout dimensions.
(
)
Mount the Insulating cover contained in the package
④
of the Operating handle.
Note
(Insulating cover mtg.screw should use what
:
was assembled to the breaker.)
2
Handle unit
(
)
When adjustment of Handle unit is not performed
as follows, the molded parts of
Handle unit and KAITENBAN may be broken.
Mount the handle unit on the front plate by attaching screws from back
side temporarily. The handle unit should be disposed in positions on the
center of the front panel.
Adjust the handle unit in every direction after mounting, if it does not
work properly with the action below
;
ON and OFF operation should be carried out smoothly.
①
When turning the handle from OFF state to the right in a few degrees,
②
it should be returned automatically. Also it should be kept indicating
OFF state even if applying light loads in the reset direction.
When opening the front plate by release operating, it should be closed
③
smoothly.
The operating handle should be parallel to the breaker.
④
After adjusting, tighten the screws completely.
5. Lock Mechanism
1
Handle unit
(
)
The Operating handle can be locked at OFF position.
It can be used the up to 3 Padlocks(A=35,40mm) or
the Lockout Hasp. When the operating handle is locked
in the OFF position by using the Padlock, the door
cannot be opened.
Handle
Padlock
How to lock the Handle unit
●
Turn the Handle toward the reset position
at the mark of case.(
) push the Lock plate(
①
return the Handle in OFF position(
).
③
Use the padlock through the Handle's hole to lock the Handle.
Note
The Lock plate operation-middle to operation load
:
may become heavy.
Please operate it until the hole of the center of
the Handle has opened.
How to release the OFF lock
●
Please detach the Padlock, turn the Handle to reset
direction until the lock plate return to the former position.
(Please check that the Lock plate has plugged up
the hole of the center of the Handle.)
2
How to lock the Operating unit
(
)
The Operating unit can be locked in "OFF" position.
Insert a Padlock into the Lock hole in OFF position only,
and lock.
A 35,40mm Padlock or a Lockout Hasp can be used.
For correct operation,please go over
this paper "Instruction Manual for V
type Operating Handle" beforehand.
There is no other application except above table.
Position
Attached Parts
of Trip
C D
E
button
1)Instruction Manual
3)Operating unit mtg.
172
30.5 86
F
nuts(2pcs)
M4
(1pc)
:
2)Operating unit mtg.
4)Handle unit mtg.
screws(2pcs)
(c)
screws(with Washer)
:
37.5 100.5
G
M4
62
(2pcs)
M5
×
:
×
The Circuit Breaker's attached screws
※
Breaker mtg.screws
M4
55 (2, 3-pole
×
M4
73 (2, 3-pole
×
Front Plate
Drilling Plan
Cutout Dimensions
Center of
Center of
Breaker
breaker handle
breaker handle
(a)
(b)
(a)
(a)
Center of
breaker
Center of
operating
handle
(a)
(a)
(a)
B
B B
Center of
operating
M4
0.7 screw
M4
0.7 screw
×
×
Left
or φ5
or φ5
handle
Hinge
2,3-pole
4-pole
Upper figure shows the relative
K
X
position of breaker and hinges,
0 or higher (5K+100) or higher
viewing from load side.
Be sure to follow these
Warning for possible electrification
instructions without fail.
under certain conditions.
V-1UV, V-1UVE
Insulating cover mtg. screw(4pcs.)
b
3.5
...
×
c
3
10
...
×
Insulating cover
mtg. screw(2pcs.)
0.6
1.0N
m
〜
・
b
c
Insulating cover
Insulating cover
Handle unit mtg. screws(with Washer)
M5
×
Front base
Handle
Padlock (to be furnished by customer)
●
B
Dimension of Padlock (mm)
C
Use any Padlock available in market.
Application
Normal
A(
size
Lock plate
35
All
types
40
A
Dimension C
8mm or less can be applied.
:
).
②
1
Handle
4
2
Padlock
Lock hole
Padlock
2. Cautionary instructions for operation
1
Do not use organic solvent to clean the Operating handle.
(
)
2
The shaft of the adjustment unit comes out when the Front plate opens.
(
)
Be careful at the check in the enclosure.
3
Be careful that the KAITENBAN and the shaft pin rotate when the Breaker is tripped
(
)
under opening the Front plate.
4
Close the Front plate in the state that the Handle positionis united with the Breaker side.
(
)
5
Operate the Handle with the power of 5N
IEC 60529 IP65
(
)
6
The door lock mechanism doesn't have strength by which the entire door of the enclosure is maintained.
(
)
Please fix the door of the enclosure with the detent tool on the enclosure side.
7
Don't operate the Handle unit under closing the Front panel, when the condition of the Operating unit was locked.
(
)
5)Insulating cover
8
It can not be operated when the mounting direction LINE and LOAD is mounted accidentally.
(
)
9
Should not trip operation to OFF position.
(
)
10
When the door is open, should not touch the live parts.
(
)
3-pole(1pc)
4-pole(1pc)
11
Normal servise condition
(
)
16
12
Do not stop the turning ON
(
)
13
The door is opened after confirming the handle is at the turning off position.(The horizontal)
(
)
3. Specification
2pcs, 4-pole
3pcs)
(a)
:
:
:
1pc)
(b)
:
:
1
Operation Lock Mechanism
(
)
2
Door Lock Mechanism
(
)
3
Mounting direction
(
)
Center of the
4
The degree of protection (IEC 60529) is IP65.
(
)
breaker handle and
5
The products of which Cat. No. include "E" are for emergency stop equipments
(
)
operating handle
and they have red Handle and yellow Front base.
φ9
6
Using the Adjustment unit as a option, it can be mounted to the different depth Panel.
(
)
7
When the trip button is pushed with the door opened, the breaker does trip.
(
)
The position of the trip button is different in the type name.
54
4. Installation for Operating handle
Front plate
1
Mounting the Operating unit
(
)
Mount the Breaker and the Operating unit in
the following matter.
Note
Make a breaker OFF position.
:
Right
Hinge
Remove a Insulating cover before installing of the
①
Circuit
Operating handle.
breaker
(Note
Be careful not to lose insulating cover mtg. screws.)
X
X
:
Adjust the protrusion for KAITENBAN to
②
mount the Operating unit on the Breaker by Operating unit
mtg. screws and Operating unit mtg.nuts.
Mount the Breaker with Operating unit on the board by
③
Breaker mtg. screws(2,3-pole
Breaker mtg. screw
1.2
M4
Operating unit mtg. screw
1.2
±
M4
×
-1-
V-2UV, V-2UVE
6. Door Lock Mechanism
10
1.2
20
N
m
:
±
%
・
1
The door can be locked in ON and TRIP position,
(
)
0.6
1.0N
m
:
〜
・
and opened in OFF position.
It is possible to open the door in ON and TRIP position
with pushing the Release parts.(Tool size
2
Withstand load to the door interlock
(
)
Withstand load to the door F(N) is 200N on the center of
Operating handle.
Otherwise, The operating handle may be destructed.
7. Adjustment unit (V-AD3S OPTION)
Adjusting the height of the Front plate by installing the Adjustment unit in
the Operating unit becomes possible.
Please cut the Shaft of the Adjustment unit from installation plane of Breaker
16(2pcs)
2.5
3.5 N
m
・ ・ ・
〜
・
according to the height of the Front plate.
Note
Operating handle for 2Poles cannot be used.
:
1
Outline
(
)
Front plate
Plate
thickness
Front plate
1.2
)
B
C
19
5
22 or 23
5.5, 6
3
Installation
(
)
3
Mark of case
Pin for
KAITENBAN
Lock plate
Joint
Joint mtg. screws
Shaft unit
-3-
m and under.
・
maintenance and others have been described to Handling and Maintenance for Molded-case circuit breakers.
・
OFF and RESET operation on the way.
・
OFF-position lock.
......
The door can be opened with the OFF position only.
............
Vertically type(ON side of breaker is upper)
..................
Insulating cover
mtg. screw (2pcs.)
mark position,
『○』
3pcs, 4-pole
4pcs).
:
:
a
Breaker mtg. screw
1.2
20
N
m
±
%
・
Protrusion for
M4
55
×
Operating
KAITENBAN
unit
20
N
m
±
%
・
73
M4
55(4-pole)
×
...
×
20
N
m
%
・
Pin of
62
KAITENBAN
width 3
thick1.8mm)
:
×
2
Shaft cutting
Dimensions
(
)
&
Front plate
3.2
〜
Min.162
Max.300
2.Fasten the Joint temporally
by Joint mtg. screws(4pcs)
Shaft
3.Insert the Shaft until
1.Adjust the Pin
the end of KAITENBAN
for KAITENBAN
to the space for Joints.
to square hole
Please insert the pin of
of Joint.
a KAITENBAN, and the pin of
a shaft according to the
same direction.
Joint
Shaft
Pin of KAITENBAN
Adjustment unit
V-AD3S
(
)
Trip button(φ4)
V-1UV, V-1UVE
V-2UV, V-2UVE
Insulating cover
mtg. screw (4pcs.)
Insulating
a
Insulating
cover
cover
Operating unit mtg.nuts
M4(2pcs.)
Excluding two poles
a
U-form projection
Shaft unit
Push the tip of the U-form
projection fully toward
Breaker
the arrowed direction by
the screw driver etc.and
Breaker mtg. screw
pull out the insulating
1.2
20
N
m
cover sliding the upper
±
%
・
direction
M4
55
×
F(N)
Release parts
F'(N)
Front plate
Hinge
Circuit
breaker
X
Size of door
P
Cutting
Enclosure
P max
length
depth
X
300 mm
P
V-1U
, V-2U
=
−
:
*
*
Shaft
X
Cutting length
175
Operating
unit
4.Fasten the Joint mtg.
screws securely.
M5
10(4pcs)
×
2.5
3.5N
m
〜
・
-2-
-4-
Need help?
Do you have a question about the V-1UV and is the answer not in the manual?