116
Appendix A: Embedded SATA RAID Technology for the Altos G310 Mk2
Problem
One of the hard drives in
a mirrored (RAID 1) array
has failed.
You insert a new drive
with no configuration
into the slot which is
already part of a
mirrored (RAID 1) array.
You insert a new drive
with no configuration
into the slot which is
already part of a striped
(RAID 0) array or there is
a striped (RAID 0) array
by itself in the system.
Suggested solution
Replace the failed drive with another drive
that has the same or greater capacity.
Press any key to enter the BIOS Configuration
Utility (Ctrl-E) to configure the new drive.
Mark the drive as one of the following:
Failed - If the AutoRebuild option is
disabled in the configuration utility
Rebuilding - If the AutoRebuild
option is enabled in the
configuration utility
Press any key to enter the BIOS Configuration
Utility (Ctrl-E) to configure the new drive.