Optical Performance Measure - Acer P1200 Service Manual

Hide thumbs Also See for P1200:
Table of Contents

Advertisement

5. HDMI Test (For P1200i/P1200B)
Procedure
Inspection item
Inspection Distance
Criteria
6. 3D Test
Procedure
Inspection item
Inspection Distance
Criteria

4-9 Optical Performance Measure

Inspection Condition
- Environment luminance: 2 Lux
- Product must be warmed up for 3 minutes
- Distances from the screen: 2.38M
- Screen Size: 60 inches diagonal
1. Test equipment
Procedure
- Check "Volume" is normal
- Check "Mute" is normal
- Test Signal : 720p,1080i
- Test Pattern : Any Pattern
- Equipment: DVD Player with HDMI output
- HDMI Test
- 1.8M ~2.5M
- Ensure the image and audio are well performed
and the color can not discolor.
- Test equipment: DVD Player
- Test Pattern : HQFS format CD
- 3D test
- < 6M
- The image should not appear noise, flicker, shadow,
shocking, abnormal color.
- Connect VGA IN port of Projector with VGA port
of Chroma by VGA cable, press "Menu" button,
get into OSD mode, the settings are as below:
- "Display mode" is "Bright", the "Format" is "4:3",
P1100C/P1200i/P1200B
Confidential
4-10