Parameter list
Pr.
Name
Torque command value
805
600 to 1400%
(RAM)
Torque command value
806
600 to 1400%
(RAM, EEPROM)
807
Speed limit selection
0 to 2
Forward rotation speed
808
0 to 400Hz
limit/speed limit
Reverse rotation speed
809
limit/reverse-side speed
0 to 400Hz, 9999
limit
Torque limit input
810
0 to 2
method selection
Set resolution
811
0, 1, 10, 11
switchover
Torque limit level
812
0 to 400%, 9999
(regeneration)
Torque limit level (3rd
813
quadrant)
Torque limit level (4th
814
quadrant)
815
Torque limit level 2
0 to 400%, 9999
Torque limit level during
816
acceleration
Torque limit level during
817
deceleration
Easy gain tuning
818
1 to 15
response level setting
Easy gain tuning
819
0 to 2
selection
820
Speed control P gain 1 0 to 1000%
Speed control integral
821
0 to 20s
time 1
822
Speed setting filter 1
0 to 5s, 9999
823
Speed detection filter 1 0 to 0.1s

Torque control P gain 1
824
(current loop
0 to 500%
proportional gain)
Torque control integral
825
time 1 (current loop
0 to 500ms
integral time)
826
Torque setting filter 1
0 to 5s, 9999
827
Torque detection filter 1 0 to 0.1s
Model speed control
828
0 to 1000%
gain
Number of machine end
829
0 to 4096, 9999 9999

encoder pulses
830
Speed control P gain 2 0 to 1000%, 9999 9999
Speed control integral
831
0 to 20s, 9999
time 2
832
Speed setting filter 2
0 to 5s, 9999
833
Speed detection filter 2 0 to 0.1s, 9999

834
Torque control P gain 2 0 to 500%, 9999
Torque control integral
835
0 to 500ms, 9999 9999
time 2
836
Torque setting filter 2
0 to 5s, 9999
837
Torque detection filter 2 0 to 0.1s, 9999
0 to 3, 24, 25,
840
Torque bias selection
9999
600 to 1400%,
841
Torque bias 1
9999
600 to 1400%,
842
Torque bias 2
9999
600 to 1400%,
843
Torque bias 3
9999
844
Torque bias filter
0 to 5s, 9999
Torque bias operation
845
0 to 5s, 9999
time
Torque bias balance
846
0 to 10V, 9999
compensation
Fall-time torque bias
847
0 to 400%, 9999
terminal 1 bias
Fall-time torque bias
848
0 to 400%, 9999
terminal 1 gain
Analog input offset
849
0 to 200%
adjustment
Brake operation
850
0 to 2
selection
Control terminal option-
851
Number of encoder
0 to 4096

pulses
Control terminal option-
852
Encoder rotation
0, 1, 100, 101

direction
853
Speed deviation time
0 to 100s

854
Excitation ratio
0 to 100%
Control terminal option-
Signal loss detection
855
0, 1

enable/disable
selection
Terminal 4 function
858
0, 1, 4, 9999
assignment
0 to 500A,
9999
Torque current/Rated
859
PM motor current
0 to 3600A,
9999
24
BASIC OPERATION
Setting
Initial
Pr.
range
value
1000%
Second motor torque
860
current/Rated PM
motor current
1000%
0
Encoder option
862

selection
60/50Hz

Control terminal option-
863
Encoder pulse division

ratio
9999
864
Torque detection
865
Low speed detection
0
Torque monitoring
866
reference
0
867
AM output filter
Terminal 1 function
9999
868
assignment
869
Current output filter
9999

Speed detection
870
hysteresis
9999
Input phase loss
872
9999
protection selection
873
Speed limit
9999

874
OLT level setting
9999
875
Fault definition
876
Thermal protector input 0, 1

2
Speed feed forward
877
control/model adaptive
0
speed control selection
Speed feed forward
60%
878
filter
0.333s
Speed feed forward
879
torque limit
9999
880
Load inertia ratio
0.001s
Speed feed forward
881
gain
100%
Regeneration
882
avoidance operation
selection
5ms
Regeneration
883
avoidance operation
9999
level
0s
Regeneration
avoidance at
60%
884
deceleration detection
sensitivity
Regeneration avoidance
885
compensation frequency
limit value
9999
Regeneration
886
avoidance voltage gain 0 to 200%
9999
888
Free parameter 1
9999
889
Free parameter 2
9999
Cumulative power
891
monitor digit shifted
times
9999
892
Load factor
9999
Energy saving monitor
893
reference (motor
9999
capacity)
Control selection during
9999
894
commercial power-
supply operation
9999
Power saving rate
895
reference value
9999
896
Power unit cost
Power saving monitor
9999
897
average time
9999
Power saving
898
cumulative monitor
clear
9999
Operation time rate
899
(estimated value)
9999
C0
FM/CA terminal
(900)
calibration

9999
C1
AM terminal calibration ―
(901)

100%
C2
Terminal 2 frequency
(902)
setting bias frequency

0
C3
Terminal 2 frequency
(902)
setting bias

2048
125
Terminal 2 frequency
(903)
setting gain frequency

C4
Terminal 2 frequency
1
(903)
setting gain

C5
Terminal 4 frequency
1s
(904)
setting bias frequency

100%
C6
Terminal 4 frequency
(904)
setting bias

0
126
Terminal 4 frequency
(905)
setting gain frequency

C7
Terminal 4 frequency
0
(905)
setting gain

C12
Terminal 1 bias
(917)
frequency (speed)


9999
C13
Terminal 1 bias (speed) 0 to 300%
(917)


C14
Terminal 1 gain
(918)
frequency (speed)

Setting
Initial
Name
range
value
0 to 500A,
9999

9999
0 to 3600A,
9999

0, 1
0
1 to 32767
1
0 to 400%
150%
0 to 590Hz
1.5Hz
0 to 400%
150%
0 to 5s
0.01s
0 to 6, 9999
0
0 to 5s
0.02s
0 to 5Hz
0Hz
0, 1
0
0 to 400Hz
20Hz
0 to 400%
150%
0, 1
0
1
0 to 2
0
0 to 1s
0s
0 to 400%
150%
0 to 200 times
7 times
0 to 1000%
0%
0 to 2
0
DC380/
300 to 1200V
DC760V
0 to 5
0
0 to 590Hz, 9999 6Hz
100%
0 to 9999
9999
0 to 9999
9999
0 to 4, 9999
9999
30 to 150%
100%
Inverter
0.1 to 55kW

rated
0 to 3600kW

capacity
0 to 3
0
0, 1, 9999
9999
0 to 500, 9999
9999
0, 1 to 1000h,
9999
9999
0, 1, 10, 9999
9999
0 to 100%, 9999 9999

0 to 590Hz
0Hz
0 to 300%
0%
0 to 590Hz
60/50Hz
0 to 300%
100%
0 to 590Hz
0Hz
0 to 300%
20%
0 to 590Hz
60/50Hz
0 to 300%
100%
0 to 590Hz
0Hz
0%
0 to 590Hz
60/50Hz
Pr.
Name
C15
Terminal 1 gain (speed) 0 to 300%
(918)

Terminal 1 bias
C16
command (torque/
0 to 400%
(919)

magnetic flux)
C17
Terminal 1 bias (torque/
0 to 300%
(919)
magnetic flux)

Terminal 1 gain
C18
command (torque/
0 to 400%
(920)

magnetic flux)
C19
Terminal 1 gain (torque/
0 to 300%
(920)
magnetic flux)

C8
Current output bias
0 to 100%
(930)
signal

C9
Current output bias
0 to 100%
(930)
current

C10
Current output gain
0 to 100%
(931)
signal

C11
Current output gain
0 to 100%
(931)
current

Terminal 4 bias
C38
command (torque/
0 to 400%
(932)

magnetic flux)
C39
Terminal 4 bias (torque/
0 to 300%
(932)
magnetic flux)

Terminal 4 gain
C40
command (torque/
0 to 400%
(933)

magnetic flux)
C41
Terminal 4 gain (torque/
0 to 300%
(933)
magnetic flux)

C42
PID display bias
0 to 500.00,
(934)
coefficient
9999

C43
PID display bias analog
0 to 300%
(934)
value

C44
PID display gain
0 to 500.00,
(935)
coefficient
9999

C45
PID display gain analog
0 to 300%
(935)
value

Input voltage mode

977
0, 1
selection
10
Parameter copy alarm
989
release
100
990
PU buzzer control
0, 1
991
PU contrast adjustment 0 to 63
0 to 3, 5 to 14,
17 to 20, 
22 to 36, 
Operation panel setting
38 to 46, 
992
dial push monitor
selection
50 to 57, 61, 62,
64, 67, 71 to 75,
87 to 98, 100
994
Droop break point gain 0.1 to 100%, 9999
Droop break point
995
0.1 to 100%
torque
997
Fault initiation
0 to 255, 9999
0, 3003, 3103,
PM parameter
998
8009, 8109,

initialization
9009, 9109
Automatic parameter
1, 2,10 to 13,
999

setting
20, 21, 9999
1000
Direct setting selection 0 to 2
Lq tuning target current
50 to 150%,
1002
adjustment coefficient
9999
1003
Notch filter frequency
0, 8 to 1250Hz
1004
Notch filter depth
0 to 3
1005
Notch filter width
0 to 3
1006
Clock (year)
2000 to 2099
101 to 131, 
201 to 229, 
301 to 331, 
401 to 430, 
501 to 531, 
601 to 630, 
1007
Clock (month, day)
701 to 731, 
801 to 831, 
901 to 930,
1001 to 1031,
1101 to 1130,
1201 to 1231



Setting
Initial
range
value
100%
0%
0%
150%
100%
0%
0%
100%
100%
0%
20%
150%
100%
9999
20%
9999
100%
0
10


100


1
58
0
9999
100%
9999
0
9999
0
9999
0
0
0
2000
101