Setting
Pr.
Name
range
NET mode operation
550
command source
0, 1, 9999
selection
PU mode operation
551
command source
1 to 3, 9999
selection
552
Frequency jump range 0 to 30Hz, 9999
553
PID deviation limit
0 to 100%, 9999 9999
PID signal operation
554
0 to 3, 10 to 13
selection
555
Current average time
0.1 to 1.0s
556
Data output mask time 0 to 20s
Current average value
0 to 500A

557
monitor signal output
0 to 3600A
reference current
Second frequency
0 to 32767,
560
search gain
9999
PTC thermistor
0.5 to 30kΩ,
561
protection level
9999
Energization time
563
(0 to 65535)
carrying-over times
Operating time
564
(0 to 65535)
carrying-over times
Second motor
0 to 400Hz,
565
excitation current break
9999
point
Second motor
566
excitation current low-
0 to 300%, 9999 9999
speed scaling factor
Second motor speed
569
0 to 200%, 9999 9999
control gain
570
Multiple rating setting
0 to 3
571
Holding time at a start
0 to 10s, 9999
4 mA input check
573
1 to 4, 9999
selection
Second motor online
574
0 to 2
auto tuning
Output interruption
0 to 3600s,
575
detection time
9999
Output interruption
576
0 to 590Hz
detection level
Output interruption
577
900 to 1100%
cancel level
Traverse function
592
0 to 2
selection
Maximum amplitude
593
0 to 25%
amount
Amplitude
594
compensation amount
0 to 50%
during deceleration
Amplitude
595
compensation amount
0 to 50%
during acceleration
Amplitude acceleration
596
0.1 to 3600s
time
Amplitude deceleration
597
0.1 to 3600s
time
175 to 215V/
598
Undervoltage level
350 to 430V
9999
X10 terminal input
599
0, 1
selection
First free thermal
0 to 590Hz,
600
reduction frequency 1
9999
First free thermal
601
1 to 100%
reduction ratio 1
First free thermal
0 to 590Hz,
602
reduction frequency 2
9999
First free thermal
603
1 to 100%
reduction ratio 2
First free thermal
0 to 590Hz,
604
reduction frequency 3
9999
Power failure stop
606
external signal input
0, 1
selection
Motor permissible load
607
110 to 250%
level
Second motor
110 to 250%,
608
permissible load level
9999
PID set point/deviation
609
1 to 5
input selection
PID measured value
610
1 to 5
input selection
Acceleration time at a
0 to 3600s,
611
restart
9999
Reverse rotation
617
excitation current low-
0 to 300%, 9999 9999
speed scaling factor
Cumulative pulse clear
635

0 to 3
signal selection
Cumulative pulse
636
1 to 16384

division scaling factor
Control terminal option-
637
Cumulative pulse
1 to 16384

division scaling factor
Cumulative pulse
638
0 to 3

storage
Brake opening current
639
0, 1
selection
Initial
Pr.
Name
value
Brake operation
640
9999
frequency selection
Second brake
641
sequence operation
9999
selection
Second brake opening
642
9999
frequency
Second brake opening
643
current
0
Second brake opening
644
current detection time
1s
Second brake operation
0s
645
time at start
Inverter
Second brake operation
rated
646
frequency

current
Second brake operation
647
9999
time at stop
Second deceleration
9999
648
detection function
selection
0
Second brake opening
650
current selection
0
Second brake operation
651
frequency selection
Speed smoothing
9999
653
control
Speed smoothing cutoff
654
frequency
Analog remote output
655
selection
656
Analog remote output 1
2
657
Analog remote output 2
9999
658
Analog remote output 3
659
Analog remote output 4
9999
Increased magnetic
660
excitation deceleration
0
operation selection
Magnetic excitation
1s
661
increase rate
Increased magnetic
0Hz
662
excitation current level 0 to 300%
Control circuit
1000%
663
temperature signal
output level
0
Regeneration
665
avoidance frequency
10%
gain
Power failure stop
668
frequency gain
10%
SF-PR slip amount
673
adjustment operation
selection
10%
SF-PR slip amount
674
adjustment gain
5s
User parameter auto
675
storage function
5s
selection
679
Second droop gain
,
9999
Second droop filter time

680
constant
Second droop function
0
681
activation selection
Second droop break
9999
682
point gain
Second droop break
100%
683
point torque
Tuning data unit
9999
684
switchover
686
Maintenance timer 2
100%
Maintenance timer 2
687
warning output set time 0 to 9998, 9999 9999
9999
688
Maintenance timer 3
Maintenance timer 3
689
1
warning output set time
Deceleration check time 0 to 3600s,
690
150%
Second free thermal
692
reduction frequency 1
9999
Second free thermal
693
2
reduction ratio 1
Second free thermal
694
3
reduction frequency 2
Second free thermal
695
reduction ratio 2
9999
Second free thermal
696
reduction frequency 3
699
Input terminal filter
Maximum motor
702
0
frequency
Induced voltage
706
1
constant (phi f)
707
Motor inertia (integer)
1
711
Motor Ld decay ratio
712
Motor Lq decay ratio
0
Starting resistance
717
tuning compensation
0
Setting
Initial
Pr.
range
value
Starting magnetic pole
0, 1
0
721
position detection pulse
width
0, 7, 8, 9999
0
724
Motor inertia (exponent) 0 to 7, 9999
Motor protection current
725
level
0 to 30Hz
3Hz
Second motor induced
738
voltage constant (phi f)
0 to 400%
130%
Second motor Ld decay
739
ratio
0 to 2s
0.3s
Second motor Lq decay
740
ratio
0 to 5s
0.3s
Second starting
741
resistance tuning
0 to 30Hz
6Hz
compensation
Second motor magnetic
0 to 5s
0.3s
742
pole detection pulse
width
0, 1
0
Second motor
743
maximum frequency
Second motor inertia
0, 1
0
744
(integer)
Second motor inertia
0, 1
0
745
(exponent)
Second motor
0 to 200%
0
746
protection current level
Second motor low-
0 to 120Hz
20Hz
747
speed range torque
characteristic selection
0, 1, 10, 11
0
1000%
1000%
Second PID action
800 to 1200%
753
1000%
selection
1000%
0, 1
0
Second PID control
754
automatic switchover
0 to 40%, 9999 9999
frequency
Second PID action set
755
100%
point
Second PID
756
proportional band
0 to 100°C
0°C
Second PID integral
757
time
0 to 200%
100%
Second PID differential
758
time
759
PID unit selection
0 to 200%
100%
Pre-charge fault
760
selection
2, 4, 6, 9999
9999
761
Pre-charge ending level 0 to 100%, 9999 9999
Pre-charge ending time 0 to 3600s,
762
0 to 500%
100%
Pre-charge upper
763
detection level
1, 9999
9999
764
Pre-charge time limit
0 to 100%, 9999 9999
Second pre-charge
765
0 to 1s, 9999
9999
fault selection
Second pre-charge
0 to 2, 10, 11, 
766
9999
ending level
20 to 22, 9999
Second pre-charge
0.1 to 100%,
767
9999
ending time
9999
Second pre-charge
0.1 to 100%,
768
9999
upper detection level
9999
Second pre-charge
769
0, 1
0
time limit
Operation panel
0 (1 to 9998)
0
774
monitor selection 1
Operation panel
775
monitor selection 2
0 (1 to 9998)
0
Operation panel
776
monitor selection 3
0 to 9998, 9999 9999
4 mA input check
777
operation frequency
1s
9999
778
4 mA input check filter
0 to 590Hz,
9999
Operation frequency
9999
779

during communication
error
1 to 100%
100%
Low speed range
0 to 590Hz,
788
torque characteristic
9999
9999
selection
Acceleration time in
1 to 100%
100%
791
low-speed range
0 to 590Hz,
Deceleration time in
9999
792
9999
low-speed range
5 to 50ms, 9999 9999
Pulse increment setting
799
for output power
0 to 400Hz,
9999
9999
Control method
0 to 5000mV/
800
selection
9999
(rad/s), 9999
10 to 999, 9999 9999
801
Output limit level
802
Pre-excitation selection 0, 1
0 to 100%, 9999 9999
Constant output range
0 to 100%, 9999 9999
803
torque characteristic
0 to 200%, 9999 9999
selection
Torque command
804
source selection
Parameter list
Setting
Initial
Name
range
value
0 to 6000μs, 
10000 to
9999
16000μs, 9999
9999
100 to 500%,
9999
9999
0 to 5000mV/
9999
(rad/s), 9999
0 to 100%, 9999 9999
0 to 100%, 9999 9999
0 to 200%, 9999 9999
0 to 6000μs, 
10000 to
9999
16000μs, 9999
0 to 400Hz,
9999
9999
10 to 999, 9999 9999
0 to 7, 9999
9999
100 to 500%, 9999 9999
0, 9999
9999
0, 10, 11, 20, 21,
50, 51, 60, 61,
70, 71, 80, 81,
90, 91, 100,
101, 1000,
0
1001, 1010,
1011, 2000,
2001, 2010,
2011
0 to 590Hz,
9999
9999
0 to 100%, 9999 9999
0.1 to 1000%,
100%
9999
0.1 to 3600s,
1s
9999
0.01 to 10.00s,
9999
9999
0 to 43, 9999
9999
0, 1
0
9999
9999
0 to 100%, 9999 9999
0 to 3600s,
9999
9999
0, 1
0
0 to 100%, 9999 9999
0 to 3600s,
9999
9999
0 to 100%, 9999 9999
0 to 3600s, 9999
9999
1 to 3, 5 to 14, 
9999
17 to 20, 22 to 36,
38 to 46, 50 to 57,
9999
61, 62, 64, 67, 
71 to 75, 87 to 98,
9999
100, 9999
0 to 590Hz, 9999
9999
0 to 10s
0s
0 to 590Hz, 9999
9999
0, 9999
9999
0 to 3600s, 9999
9999
0 to 3600s, 9999
9999
0.1, 1, 10,
1kWh
100, 1000kWh
0 to 6, 9 to 14,
20, 100 to 106, 
20
109 to 114
0 to 400%, 9999 9999
0
0 to 2, 10, 11
0
0 to 6
0
23