Internal Microphone Failure - Acer Aspire One AO532h Service Manual

Table of Contents

Advertisement

Internal Microphone Failure

If the internal Microphone fails, perform the following actions one at a time to correct the problem. Do not
replace non-defective FRUs:
Microphone Problems
If internal or external Microphones do no operate correctly, perform the following actions one at a time to
correct the problem.
1.
Check that the microphone is enabled. Navigate to Start
Sound and select the Recording tab.
2.
Right-click on the Recording tab and select Show Disabled Devices (clear by default).
3.
The microphone appears on the Recording tab.
4.
Right-click on the microphone and select Enable.
5.
Select the microphone then click Properties. Select the Levels tab.
6.
Increase the volume to the maximum setting and click OK.
7.
Test the microphone hardware:
a.
Select the microphone and click Configure.
b.
Select Set up microphone.
c.
Select the microphone type from the list and click Next.
d.
Follow the onscreen prompts to complete the test.
8.
If the Issue is still not resolved, see "Online Support Information" on page 213.
Chapter 4
Start
Check M/B
Mic cable
OK
Check MIC
wire of LCD
module
Swap M/B
OK
Re-assemble
the MIC cable
NG
to M/B
OK
Swap MIC wire
of LCD module
NG
Control Panel
Hardware and Sound
111

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nav50 series

Table of Contents