Wall Type <Concrete>
The <Concrete> wall type is suitable for applications in dry concrete. It displays plastic
pipes and metal objects as well as electrical and other cables. Empty plastic pipes with a
diameter of less than 2 cm may not be displayed.
When selecting the wall type, you can additionally set the maximum measuring depth
between 8 cm and 20 cm.
Wall Type <Drywall>
The <Drywall> wall type is suitable for detecting timber joists and metal supports, as
well as electrical and other cables in drywalls (wood, plasterboard, etc.). Filled plastic
pipes and wooden beams appear identical on the display. Empty plastic pipes are not re-
cognised.
Wall Type <Panel Heating>
The <Panel Heating> wall type is especially suitable for detecting metal, metal-compos-
ite and water-filled plastic pipes and electrical cables. Empty plastic pipes are not dis-
played.
Wall Type <Vertical Coring Brick>
The <Vertical Coring Brick> wall type is especially suitable for applications in vertically
perforated bricks. Vertically perforated bricks are bricks with many small, mostly ver-
tical, cavities. It displays metal objects, electrical and other cables, as well as water-filled
plastic pipes. Cavities or empty plastic pipes may not be displayed.
Wall Type <Horizontal Coring Brick>
The <Horizontal Coring Brick> wall type is especially suitable for applications in hori-
zontally perforated bricks. Horizontally perforated bricks are bricks with a few, mostly
horizontal, cavities. It displays flat lying metal objects, electrical and other cables, as well
as water-filled plastic pipes up to a maximum measuring depth of 5 cm. Cavities or
empty plastic pipes may not be displayed.
Wall Type <Early Age Concrete>
The <Early Age Concrete> wall type is especially suitable for applications in concrete
which has not yet fully cured and dried. Metal objects are displayed up to a maximum
measuring depth of 6 cm. Plastic pipes and cables may not be displayed. A distinction
between live and voltage-free conductors is not possible.
Please observe that concrete requires several months to cure and dry completely.

Change the view

To change the view, repeatedly press the top (17) or bottom select button (12) until the
required view is displayed. Press the red start button (16) to accept the selection.