24v electronic control unit for sliding gates and barriers (24 pages)
Summary of Contents for SEA GATE 2 DG R1B
Page 1
GATE 2 DG R1B CONTROL UNIT FOR ONE OR TWO OPERATORS 230V/115V MANAGEMENT SEA USA Inc. 10850 N.W. - 21st - unit 160 - Doral - MIAMI Florida (FL) - 33172 - USA Telephone : ++1-305.594.1151 ++1-305.594.7325 Toll free: 800.689.4716 www.sea-usa.com...
Page 2
IMPORTANT SAFETY INFORMATION GENERAL SAFETY PRECAUTIONS The following precautions are an integral and essential part of the product and must be supplied to the user; Read them carefully as they contain important indications for the safe installation, use and maintenance. 1.
Page 3
GENERAL SAFETY INFORMATION An appliance shall be provided with an instruction manual. The instruction manual shall give instructions for the installation, operation, and user maintenance of the appliance. The installation instructions shall specify the need for a grounding-type receptacle for connection to the supply and shall stress the importance of proper grounding.
Page 4
The installer shall follow the provided instructions thoroughly. SEA products must only be used to automate doors, gates and wings. Any initiative taken without SEA USA Inc. explicit authorization will preserve the manufacturer from whatsoever responsibility.
Page 5
NOTES: 1. The same type of device shall not be used for both entrapment protection means. Use of a single device to cover both the opening and closing directions is in accordance with the requirement; however, a single device is not required to cover both directions.
Page 6
INDEX CHAPTER PAGE CHAPTER PAGE Connections Connections on EXP Contacts SEM 2 management unit Connections on CN1 Temperature probe Start Additional limit switches Partial opening Start Potentiometer Stop Additional functions Photocells 1 and 2 10.1 Amperometric management 24V AUX 10.2 Surge Protector circuit Timer Display/programming...
Page 7
COMPONENTS motor control - triac input / output motor control - triac limit switch - 24V - electric lock motors relay motor 1 - capacitor M1 courtesy light relay motor 2 - capacitor M2 photocell self-test relay courtesy light electric lock relay power supply 1 A accessories fuse encoder...
Page 8
ENGLISH Italiano International registered trademark n. 804888 1 - CONNECTIONS WARNING: CONNECT ALL DEVICES WITH SWITCHED-OFF CONTROL UNIT 14 15 16 17 18 19 20 21 22 23 31 32 33 34 35 36 37 38 39 40 LSO1 LSC1 LSO2 LSC2 COM 24V~ 24VPH LOCK CLM1 NM1 OPM1...
Page 9
ENGLISH Italiano International registered trademark n. 804888 3 - CONNECTIONS ON CN1 3.1 - START (N.O.) On clamps 3 and6 The automation can be opened or closed through an impulse transmitted to this input (via key button, keyboard, etc.). To connect other START devices (for ex.
Page 10
ENGLISH Italiano International registered trademark n. 804888 3.7 - 24V FLASHING LIGHT - MAX 3W EXAMPLE OF LAMP AND On clamps 11 and 13 SAFETY EDGE It warns of the gate movement by performing 1 blink per CONNECTION second on opening, 2 blinks per second on closing and remaining on steady during pause.
Page 11
ENGLISH Italiano International registered trademark n. 804888 3.11 - SAFETY LOOP EXAMPLE OF SAFETY LOOP CONNECTION Safety Exit Loop (Loop 1) Connection scheme of the C C2 C2 1 reader loop detector 7 = Photocell 1 contact (N.C.) Loop 1 6 = Common Safety Exit Loop1...
Page 12
ENGLISH Italiano International registered trademark n. 804888 3.13 - EXTERNAL RECEIVER EXAMPLE OF EXTERNAL RECEIVER CONNECTION An external receiver can be connected to the control unit, according to the connection diagram on the side. In this case, it is necessary to set the 94-24VAUX menu to t h e "...
Page 13
ENGLISH Italiano International registered trademark n. 804888 4 - CONNECTIONS ON CN2 4.1 - LIMIT SWITCH For the limit switch function, both the closing and opening limit switches must be 14 15 16 17 18 19 20 connected. It is also possible to activate the anti-intrusion function, which is linked to the presence of one limit switch at least;...
Page 14
ENGLISH Italiano International registered trademark n. 804888 CONNECTIONS ON CN3 AND CN4 5.1 - OPERATORS CONNECTION ON THE CONTROL UNIT MOTOR 1 MOTOR 2 CLM1 = CLOSE CLM2 = CLOSE = NEUTRAL = NEUTRAL 31 32 33 34 35 36 37 38 39 40 OPM1 OPM2 = OPEN...
Page 15
ENGLISH Italiano International registered trademark n. 804888 7 - CONNECTIONS ON CN6 7.1 -CONTROL UNIT CONNECTION Fuse 3,6A delayed on 230V~ power supply Fuse 6,3A delayed on 115V~ power supply 115V~ ± 5% CAUTION!: for the connection to the power grid refer to the regulations 230V~ ±...
Page 16
ENGLISH Italiano International registered trademark n. 804888 CONNECTIONS ON 9.1 - «SEM 2» MANAGEMENT UNIT CONNECTION The «SEM 2» management unit can be 24V~ / (ac/dc) connected through the EXP connector or 230V~ The SEM 2 unit manages: - The TRAFFIC LIGHT functions - The COURTESY LIGHT functions - T h e V E R T I C A L E L E C T R I C L O C K functions...
Page 17
ENGLISH Italiano International registered trademark n. 804888 9.4 - «POSITION GATE» CONNECTION THROUGH «LSE» or «LE» UNITS Through the LSE management unit (or LE Example: «LSE» MANAGEMENT UNIT management unit) it is possible to connect the «POSITION GATE», a potentiometer able to manage the correct position of the gate and the reversing on obstacle POSITION GATE can be enabled on menu...
Page 18
ENGLISH Italiano International registered trademark n. 804888 9.6 - «POSITION GATE» POTENTIOMETER PARAMETERS SETTING menu 33-OPENING SENSITIVITY MOTOR 1 adjusts the intervention time in opening menu 34- CLOSING SENSITIVITY MOTOR 1 adjusts the intervention time in closing menu 35-OPENING SENSITIVITY MOTOR 2 adjusts the intervention time in opening menu 36- CLOSING SENSITIVITY MOTOR 2...
Page 19
ENGLISH Italiano International registered trademark n. 804888 10.2 - «I/O SURGE PROTECTOR» CIRCUIT CONNECTION OUTPUT It is possible to connect the «SURGE GROUND CONNECTIONS ON CONTROL UNIT PROTECTOR» device, to protect up WIRE 24V DC ACCESSORIES to 6 inputs + 24V power supply from CONTACT 1 (Eg.
Page 20
ENGLISH Italiano International registered trademark n. 804888 12 - BASIC MENU FUNCTIONS PRESS TO CONFIRM MOVE THROUGH ENGLISH AND RETURN TO THE LANGUAGE MAIN MENU DOWN Skip this step if no need Tx programming TO CONFIRM AND EXIT Press the TX PRESS START MEMORIZED...
Page 21
ENGLISH Italiano International registered trademark n. 804888 13 - INPUT STATUS CHECK AND MANAGEMENT The input status check menu is displayed at the start of the control unit (for more details see chapter 11). Each input corresponds to a fixed position on the display, according to the diagram below and can be NORMALLY OPEN (N.O.) or NORMALLY CLOSED (N.C.) NORMALLY OPEN (N.O.)
Page 22
ENGLISH Italiano International registered trademark n. 804888 13.2 - GATE 2 DG R1B INPUT MANAGEMENT MENU IT IS POSSIBLE TO ENABLE OR DISABLE THE INPUTS WITHOUT REPEATING THE SELF LEARNING LANGUAGE BACK TO THE START ENABLED STARTING MENU START BACK TO THE...
Page 23
ENGLISH Italiano International registered trademark n. 804888 14 - WORKING TIMES SELF-LEARNING POTENTIALLY DANGEROUS PROCEDURE. TO BE PERFORMED EXCLUSIVELY BY SPECIALIZED INSTALLERS AND IN SAFETY CONDITIONS NOTE PRELIMINARI: It is not necessary to jumper Limit switches, Photocells, Stop or Safety Edges inputs if not used - Check the correct operation of all accessories (Photocells, Push buttons etc.) 14.1 - QUICK START The electronic unit on board the SLIDING...
Page 24
ENGLISH Italiano International registered trademark n. 804888 14.4 - SELF-LEARNING WITH ENCODER OR POTENTIOMETER Working times self-learning through detection of the pulses by Encoder or Potentiometer PRELIMINARY NOTES: - Check that the 32-ENCODER menu is «ON»; access submenus 47 - 48 - 49 - 50 and check the correct reading of the pulses;...
Page 25
PRELIMINARY NOTES: 1) Once the password is enabled, the menu cannot be adjusted; 2) If You forgot the password, contact the SEA technical assistance; SEA will evaluate whether or not to provide the procedure for the control unit unlocking 3) Password CAN NOT be set through the JOLLY 3 programmer...
Page 26
ENGLISH Italiano International registered trademark n. 804888 17 - RECEIVERS AND REMOTE CONTROLS SEA PLUG-IN RECEIVERS MAX NUMBER OF USERS 16 USERS Without additional memory RF UNI 800 USERS With MEMO RF additional memory 100 USERS Fix Code RF UNI PG (Old Model)
Page 27
ENGLISH Italiano International registered trademark n. 804888 17.2 - REMOTE CONTROLS PROGRAMMING TABLE PROGRAMMING PRESS THE BUTTON MENU TO BE STORED «START» COMMAND PRESS START STORED MUST ALWAYS BE LANGUAGE TRANSMITTERS BUTTON STORED ON THE TX PRESS THE BUTTON TO BE STORED PROGRAMMING OF PARTIAL PRESS...
Page 28
MENU FUNCTIONS TABLE - GATE 2 DG R1B MENU DESCRIPTION DEFAULT NOTE Italiano Italian English English Français French 1 LANGUAGE English Español Spanish Dutch Dutch Polish Polish Start Start Partial opening Partial opening External module External module Stop Stop Pressed once, it stops the gate.
Page 29
SPECIAL MENU PRESS UP AND DOWN FOR 5 SECONDS AT THE SAME TIME TO ENTER OR TO EXIT THE SPECIAL MENU SPECIAL MENU DESCRIPTION DEFAULT NOTE LEAF DELAY IN Adjustable from OFF to 6 seconds OPENING LEAF DELAY IN Adjustable from OFF to 20 seconds CLOSING By increasing the torque, more strength will be required to OPENING TORQUE...
Page 30
SPECIAL MENU DESCRIPTION DEFAULT NOTE To adjust the Encoder or Potentiometer intervention time on 10% (Fast intervention) OPENING 99% (Slow intervention) Motor 1 in opening SENSITIVITY MOTOR Disabled Off (Intervention excluded) To adjust the Encoder or Potentiometer intervention time on 10% (Fast intervention) CLOSING SENSITIVITY 99% (Slow intervention)
Page 31
SPECIAL MENU DESCRIPTION DEFAULT NOTE 63 DECELERATION To adjust the change from normal speed to slowdown speed 100% 100% Acceleration ramp. 64 ACCELERATION 100% 100% To adjust the motor start For menu from 65 to 68 see menu 32-Encoder = Off (They are visible even with 32-Encoder set ON) To disable the anti-overlapping control of the leaves allowing their separate control 69 ANTI OVERLAP...
Page 32
SPECIAL MENU DESCRIPTION DEFAULT NOTE 84 BRAKE 100% To adjust the braking on the limit switches Only closing To enable the pre-flashing only before closing 85 PRE-FLASHING 0.0 s 5.0 s To set the pre-flashing duration Normal Normal Light Warning lamp function 86 FLASHING LIGHT Normal Always...
Page 33
SPECIAL MENU DESCRIPTION DEFAULT NOTE Safety Edge 1 Self-test enabled only on safety edge 1 Safety Safety Edge 2 Self-test enabled only on safety edge 2 SAFETY EDGE Edges 1 SELF-TEST Safety Edges 1 and 2 Self-test enabled on safety edges 1 and 2 and 2 Disabled If the photocell is occupied during closing, the gate reverses the...
Page 34
SPECIAL MENU DESCRIPTION DEFAULT NOTE Normal Normal N.C. contact To enable the safety edge protected by a 8K2 resistor 100 SAFETY EDGE 1 Normal 8K2 Double To enable two safety edges protected by a 8K2 resistor Photo 1 10K To enable the photocell protected by a 10K resistor Photo 1 10K Double To enable two photocells protected by a 10K resistor Normal...
Page 35
SPECIAL MENU DESCRIPTION DEFAULT NOTE In case of a STOP command when the gate is on its halfway, the 116 REPEAT LEAF DELAY leaves will repeat the "leaf delay" set on menus 26-27 In case of power failure, if the gate has been manually open, it 117 ALWAYS CLOSE 240 seconds closes only after the set time has elapsed (from 0 to 240...
Page 36
ENGLISH Italiano International registered trademark n. 804888 ALARMS The control unit advises about faults by a message on the display. The table below shows which faults are advised and what to do in the event of a malfunction. However, it is possible to read the last 10 fault warnings by accessing the 106-DIAGNOSTIC menu Note 1: To exit the alarms display press OK If the warning signal does not disappear, carry out all the checks required for that error or disconnect the...
Page 37
ENGLISH Italiano International registered trademark n. 804888 TROUBLESHOOTING Advices Make sure all Safeties are turned ON Problem Found Possible Cause Solutions a) Check the connections or the jumpers on the connections of Operator doesn’t respond to a) Check the connected N.C. contacts the safety edge or of the stop and of the photocell if connected any START impulse b) Burnt fuse...
Page 38
ENGLISH Italiano International registered trademark n. 804888 Advices Make sure all Safeties are turned ON Problem Found Possible Cause Solutions a) Check menu for encoder parameters "Encoder Par" shall be from a low value +/- 10 (gate completely closed) to "Encoder a) ENCODER is not working properly if It's tot"...
Page 39
PRICES: Prices are based on the Price List in force. Discounts and quotation from Sales Dep. and other selling branches must be approved by SEA. Prices are F.O.B SEA Warehouse in Miami and do not include shipments costs. SEA reserves the right to modify the price list at any time and provide notice to its sales network.
Page 40
SEA USA Inc. 10850 N.W. 21st - unit 160 - DORAL - MIAMI Florida (FL) 33172 Phone: ++1-305.594.1151 Toll Free: 800.689.4716 www.sea-usa.com sales@sea-usa.com...