Output signal
Terminal
Terminal name
Symbol
A1,
Relay output 1 (fault
B1,
output)
C1
A2,
B2,
Relay output 2
C2
RUN
Inverter running
SU
Up to frequency
OL
Overload warning
Instantaneous power
IPF
failure
FU
Frequency detection
Open collector output
SE
common
For meter
FM

NPN open
collector output
AM
Analog voltage output
CA
Analog current output


Terminal FM is provided in the FM-type inverter.

Terminal CA is provided in the CA-type inverter.
Terminal function description
1 changeover contact output that indicates that an inverter's
protective function has been activated and the outputs are
stopped.
Fault: discontinuity across B and C (continuity across A and C),
Normal: continuity across Band C (discontinuity across A and C)
1 changeover contact output
Switched to LOW when the inverter output frequency is equal to or
higher than the starting frequency (initial value 0.5 Hz). Switched to
HIGH during stop or DC injection brake operation.
Switched to LOW when the output
frequency is within the set frequency
range 10% (initial value). Switched to
HIGH during acceleration/deceleration
and at a stop.
Switched to LOW when stall prevention
is activated by the stall prevention
function. Switched to HIGH when stall
prevention is canceled.
Switched to LOW when an
instantaneous power failure occurs or
when the undervoltage protection is
activated.
Switched to LOW when the inverter
output frequency is equal to or higher
than the preset detection frequency,
and to HIGH when it is less than the
preset detection frequency.
Common terminal for terminals RUN, SU, OL, IPF, FU
Outputs a selected monitored item
(such as output frequency) among
several monitored items. The signal is
not output during an inverter reset.
The output signal is proportional to the
magnitude of the corresponding
monitor item.
Use Pr.55, Pr.56, and Pr.866 to set full
scales for the monitored output
frequency, output current, and torque.
(Refer to the FR-A800 Instruction
Manual (Detailed).)
Rated specification
Contact capacity 230
VAC 0.3 A (power factor
= 0.4)
30 VDC 0.3 A
Permissible load 24 VDC
(maximum 27 VDC) 0.1 A
(The voltage drop is 2.8 V
at maximum while the
signal is ON.)
Fault code (4 bits)
LOW is when the open
output.
collector output transistor
(Refer to the FR-A800
is ON (conducted).
Instruction Manual
HIGH is when the
(Detailed).)
transistor is OFF (not
conducted).
Permissible load current
Output item:
2 mA
Output frequency (initial
For full scale
setting)
1440 pulses/s
This terminal can be
Maximum output pulse
used for open collector
50k pulses/s
outputs by setting
Permissible load current
Pr.291.
80 mA
Output signal 0 to 10
VDC, Permissible load
current 1 mA
(load impedance 10 k or
Output item:
more) Resolution 8 bits
Output frequency (initial
setting)
Load impedance 200  to
450 
Output signal 0 to 20
mADC