Vacmaster VOC507S Operator's Manual page 10

Wet/dry vacuum
Hide thumbs Also See for VOC507S:
Table of Contents

Advertisement

Available languages

Available languages

1. Verify that the power cord is disconnected from the outlet. Make sure that the collection tank is
clean and free of dust and dirt (Fig. 1).
2. Remove the reusable cloth filter, then carefully install the foam wet filter over the filter cage and
place the power head back on the collection tank. For foam wet filter installation instructions,
see page 13 (Fig. 2).
DO NOT USE THE REUSABLE CLOTH FILTER FOR LIQUID VACUUMING.
OPERATING INSTRUCTIONS: WET VACUUMING
3. Insert the locking end of the hose into the vacuum port on the collection tank and lock into
place.
4. Push the required attachment onto the free end of the hose or extension wand (Fig. 3).
5. Verify that the switch is in the 'O' OFF position before plugging the power cord into the power
outlet. Plug the power cord into the outlet (Fig. 4 & 5).
6. Turn the motor on by flipping the switch to the 'I' ON position (Fig. 6).
7. Once you have completed vacuuming, flip the switch to the 'O' OFF position and unplug the
power cord from the outlet.
8. After use, empty the collection tank, clean and dry the inside and outside of the collection tank
(Fig. 7).
IMPORTANT! When vacuuming large quantities of liquids, do not immerse the nozzle completely
in the liquid; leave a gap at the tip of the nozzle opening to allow air inflow. The machine is fitted
with a float valve that stops the suction action when the collection tank reaches its maximum
capacity. You will notice an increase in motor speed. When this happens, turn off the machine,
disconnect from power supply, and drain the liquid into a suitable receptacle or drain. To continue
vacuuming, refit the power head to the collection tank. After wet vacuuming, turn the machine
off and remove plug from power supply. Empty the collection tank, clean and dry the inside and
outside before storage.
REMEMBER! The foam wet filter must be removed after wet vacuuming and the reusable cloth
filter must be installed before dry vacuuming again.
10