Automation Expert
MX2NC PLC User Manual
Thank you for choosing the Coolmay MX2NC series PLC. This manual mainly explains
the features, general specifications and wiring methods of MX2NC series PLC. Detailed
programming information please refer to "CoolmayMX2NC PLC Programming Manual".
MX2NC series PLC has the following features:
1. Highly integrated and super functional. Maximum support 16 digital input and 16
digital output.
2. Support multi-channel high-speed counting and high-speed pulse functions, high-
speed counting normally 6 channels single-phase 10KHz or 2 channels AB (Z) phase
10KHz; high-speed pulse normally 4 channels 10KHz.
3. Support special encryption. Setting 12345678 as password can thoroughly prevent the
data from being read. (Note:Only supports 8-bit password encryption)
4. Support for external interrupts and watchdog functions.
5. Use DIN rail (35mm width) to install.
6. Use pluggable terminals with a pitch of 3.5mm, which is convenient for wiring.
Product Information
MX2NC
-
32
M
R
◆
Naming rules
1
2
3
4
1. Series
MX2NC: MX2NC series PLC
2. I/O Points
32: 16DI/16DO
3. Module
M: Main module
4. DO type
R: relay / T: transistor
◆
Basic parameters
Digital value
High-speed counting
COM port
MX2NC series
standard PLC
AB(Z)
DI
DO
RS232
Single-phase
phase
6 channels
2 channels
1
MX2NC-16M
8
8
10KHz
10KHz
6 channels
2 channels
1
MX2NC-32M
16
16
10KHz
10KHz
MT means transistor output, MR means relay output.
Electrical Parameters
Input Voltage
DC 24V
Digital Input Index
Isolation Method
Photoelectric Coupling
Input Impedance
High-speed input 3.3KΩ
Continued from the previous table)
(
Input ON
Input OFF
Filter Function
High - speed Counting
Input Level
Max Current
Load Voltage
Circuit Insulation
On Respond Time
Mechanical Life (without load)
Electrical Life (rated load )
Output Level
Max Current
Load Voltage
Circuit Insulation
Isolation Voltage
(power supply-external terminal)
On Response Time
High-speed Output Frequency
Output Common
Table 1: basic parameters
High-speed
Size
Programming Port
pulse output
Dimensions
Output
(mm)
Operating Temperature
Relative Humidity
4 channels
90*65*32
Storage Temperature
10KHz
Vibration Frequency
Mechanical Design Reference
4 channels
90*65*32
10KHz
◆
Installation size
Table 2:electrical parameters
Common input 4.3ΚΩ
Electric current of common
Electric current of high-speed
input is higer than 4.5mA
input is higher than 3.5mA
High-speed input and normal input current are less than than 1.5mA
With filter function, the filter time can be set among 0-100ms, defaulted as 10ms
Normally 6 single-phase (X0-X5) 10KHz or 2 AB (Z) phase 10KHz;
Low level NPN, common terminal is negative
Digital Relay Output Index
2A/point, 5A/8point COM
Below DC30V/ Below AC220V
Relay Mechanical Insulation
About 10ms
10 million times
300 thousand times
Normally open dry contact output, COM port can be connected to positive or negative
Digital Transistor Output Index
0.5A/point, 1.6A/8point COM
DC12V~48V
Optocoupler Insulation
1500VAC
High-speed output: 10μs / Other: 0.5ms
Y0-Y3 is normally 10KHz
COM port connected to the negative end
External Interface
Comes with 1 RS232 programming port
Environment
0℃~50℃
5%
~95%RH
-20°C~70°C
10-57Hz, amplitude 0.035mm; 57Hz-150Hz, acceleration 4.9m/s²
(10 times each in X, Y, and Z directions, a total of 80 minutes each)
90
32
Dimensions: 90*65*32(mm)
Installation size: DIN rail (35mm) installation
Diagram 1 Installation dimension drawing
Electrical Design Reference
1
2
2
3
3
Diagram 2 Product structure
1. Programming port Rs232
2. Terminal block of digital input
4. PWR: Power-on state
RUN: The light is on when the PLC is running
ERR: The indicator light will flash when the program
is wrong (the indicator light will be on when the CPU is wrong)
◆
Hardware interface
RUN
ERR
PWR
X
00
01
02
03
04
05
06
07
Y
00
01
02
03
04
05
06
07
Diagram 3 Hardware interface diagram
MX2NC series PLC PIN definition
Pin NO.
Signal
Description
4
RXD
Receive date
5
TXD
Send data
8
GND
Ground
65
◆
Rs232 (PLC programming port): Supports Mitsubishi programming port protocol, which can be used to download
PLC programs or to communicate with devices that support Mitsubishi programming port protocol.
Terminal wiring specifications: 22-14AWG wire. The terminals of this series of models are all pluggable
terminals. Please refer to the product silk screen for the interface identification of special models.
1
4
5
2
6
3
7
3.Terminal block of digital output
5. RUN/STOP PLC operation switch
6. T erminal block for power input signal
7. 35mm rail installation place
RUN
X
ERR
PWR
10
11
X
12
00
13
01
14
02
15
03
16
04
17
05
Y
06
07
10
Y
11
12
00
13
01
14
02
15
03
16
04
17
05
06
07
① ②
③ ④ ⑤
⑧
⑥ ⑦
Diagram 4 PLC programming
Need help?
Do you have a question about the MX2NC PLC and is the answer not in the manual?
Questions and answers