Panasonic PAW-160MAH2L Installation Instructions Manual page 43

Air handling unit kit
Table of Contents

Advertisement

Technical data and limitations – PACi systems –
AHU Kit
Outdoor unit – PACi Elite
Nominal cooling capacity
Nominal heating capacity
Piping connections
Liquid pipe
Gas pipe
Piping length
Min / Max
Precharged length (R32)
Max
Additional refrigerant charge (R32) due to extended piping
length
Ambient temperature
Cooling (Min / Max) °C DB
Heating (Min / Max) °C WB
AHU unit under "standard conditions"
Air volume flow
Cooling (Min / Max) m³/h
Air intake temperature
Cooling (Min / Max) °C DB
1
Heating (Min / Max) °C DB
AHU DX coil heat exchanger volume Min / Max
Heat exchanger face area
Min / Max
AHU unit under "special conditions A
"
2
Air volume flow,
Cooling (Min / Max) m³/h
subject to restrictions
2
Air intake temperature
Cooling (Min / Max) °C DB
1
Heating (Min / Max) °C DB
AHU unit under "special conditions B
"
3
AHU DX coil heat exchanger volume,
Min / Max
subject to restrictions
3
Additional refrigerant charge (R32) due to larger heat
exchanger volume
Max. additional refrigerant charge (R32)
Max. pipe length
Max. ambient temp. for pump down
360 510 700 780 870 900 990 1080 1140 1200 1320 1450 1500 1600 1700 1800 1900 2000 2160 2280 2300 2400 2500 2600 2700 2900 3000 3500 4000 4320 4440 4600 5040 5400
Outdoor unit
U-60PZ2E5
U-71PZ2E5
U100-PZ2E5/8
U125-PZ2E5/8
U140-PZ2E8
U-36PZH2E5
U-50PZH2E5
U-60PZH2E5
U-71PZH2E5/8
U-100PZH2E5/8
U-125PZH2E5/8
U-140PZH2E5/8
U-200PZH2E8
U-250PZH2E8
Maximum allowed air volume flow
under "Standard conditions"
1 Air intake temperature entering the AHU DX coil heat exchanger
2 Special conditions A: Using an AHU unit with a higher maximum allowed air volume flow is subject to a restriction of the
"Air intake temperature" to 30 °C DB (instead of 32 °C WB under standard conditions).
3 Special conditions B: Using an AHU DX coil heat exchanger with a larger volume is subject to the following restrictions:
Note: The AHU DX coil must be designed according to Panasonic specification.
Calculation example for total additional refrigerant charge (R32)
Unit: U-60PZ2E5
Pipe length: 40 metres
AHU DX coil (supplied by AHU manufacturer): 1,7 dm
Refrigerant charge at shipment fitted for pipe length within 30 m
Pipes additional refrigerant charge: 0.035 kg/m
AHU Kit – Installation Instructions – 09/2021
U-71PZH2E8 U-100PZH2E8 U-125PZH2E8 U-140PZH2E8 U-200PZH2E8 U-250PZH2E8
kW
7.1
kW
8.0
Inch (mm)
3/8 (9,52)
Inch (mm)
5/8 (15,88)
m
5 / 50
m
30
g/m
45
-15 / 46
-20 / 18
780 / 1,320
18 / 32
°C WB
14 / 25
16 / 30
dm
– / 1.8
3
m
– / –
2
780 / 1,700
18 / 30
°C WB
14 / 25
16 / 30
dm
– / 2.2
3
kg/dm
0.83
3
kg
0.33
m
40
°C
35
Higher maximum allowed air volume flow under "Special conditions A
Maximum allowed air intake temperature at AHU DX coil heat exchanger in cooling mode is restriced to 30 °C DB.
an additional refrigerant charge (R32), which is required irrespective of an additional refrigerant charge
which might be needed due to an extended piping length (see calculation example below)
AND a reduced maximum pipe length
AND an ambient air temperature limit above which it may not be possible to pump down the complete
refrigerant charge (including all additional refrigerant) into the outdoor unit.
R32
(cont.)
PAW-280PAH2(L/M) or PAW-280PAH3M
10.0
12.5
14.0
11.2
14.0
16.0
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
5 / 85
5 / 85
5 / 85
30
30
30
45
45
45
-15 / 46
-15 / 46
-15 / 46
-20 / 18
-20 / 18
-20 / 18
900 / 2,160
1,140 / 2,280 1,200 / 2,400 2,160 / 4,320 2,280 / 5,040
18 / 32
18 / 32
18 / 32
14 / 25
14 / 25
14 / 25
16 / 30
16 / 30
16 / 30
1.7 / 2.1
1.7 / 2.1
1.7 / 2.1
0.43 / 0.51
0.43 / 0.51
0.43 / 0.51
900 / 2,400
1,140 / 2,600 1,200 / 2,700 2,160 / 4,600 2,280 / 5,400
18 / 30
18 / 30
18 / 30
14 / 25
14 / 25
14 / 25
16 / 30
16 / 30
16 / 30
1.7 / 3.0
1.7 / 3.0
1.7 / 3.0
0.83
0.83
0.83
0,74
0,74
0,74
65
65
65
43
43
43
Air volume flow m³/h
":
2
3
Product description
19.5
23.2
22.4
28.0
3/8 (9,52)
1/2 (12,7)
1 (25,4)
1 (25,4)
5 / 90
5 / 60
30
30
60
80
-15 / 46
-15 / 46
-20 / 24
-20 / 24
18 / 32
18 / 32
n/a
n/a
16 / 30
16 / 30
2.3 / 4.3
2.7 / 4.3
0,54 / 1.0
0.66 / 1.0
18 / 30
18 / 30
n/a
n/a
16 / 30
16 / 30
2.3 / 5.7
2.7 / 7.1
0.83
0.83
1.16
2.32
90
60
n/a
n/a
3
43