Maintenance And Service; General Information; Replacing The Module; Disconnecting The Wiring - Bosch Rexroth IndraControl S67 Manual

Digital module high speed 4 inputs/outputs – 0.2 a (4×m12)
Hide thumbs Also See for Rexroth IndraControl S67:
Table of Contents

Advertisement

DOK-CONTRL-S67DIO4M12H-AP02-EN-P
Rexroth IndraControl S67 Digital Module High Speed 4 Inputs/Outputs – 0.2 A (84×M12)
12

Maintenance and Service

12.1

General Information

12.2

Replacing the Module

12.2.1
General Information
12.2.2

Disconnecting the Wiring

12.2.3

Removing the Field Bus Coupler from the System

12.2.4

Removing the Field Bus Coupler from the Carrier Plate

This section contains information on maintenance and service.
To replace a S67-DIO4-HS-M12 module in the event of version change, etc.,
proceed as described in the following chapters.
Before removing the connectors, clean the S67-DIO4-HS-M12 module to en‐
sure that no dirt or other material comes in contact with the connections. This
could damage the contacts.
To unplug the cables, proceed as follows:
1. Disconnect the power supply from those devices on which you have
mounted the S67-DIO4-HS-M12 module.
CAUTION
Even when taking into account derating, high surface temperatures on
the metallic connection sockets and on the enclosure can arise during
operation. If the IndraControl S67 component has been in operation, al‐
low the component to cool off before touching it.
2. Unscrew all screw connections and remove the cables.
To remove the S67-DIO4-HS-M12 module from the system, proceed as fol‐
lows:
1. Disconnect the power supply from those devices on which you have
mounted the S67-DIO4-HS-M12 module.
2. Release the S67-DIO4-HS-M12 module from the system by unscrewing
the M4 screws.
In order to keep a clear representation, the mounting rail adapter in the figure
below (B, C) is shown without the S67-DIO4-HS-M12 module.
If the S67-DIO4-HS-M12 module is mounted on a mounting rail, proceed with
the removal as follows:
1. Disconnect the power supply from those devices on which you have
mounted the S67-DIO4-HS-M12 module.
2. To remove the S67-DIO4-HS-M12 module, press down the release eye‐
bolt of the mounting rail adapter using a slot screwdriver (B) and remove
it from the rail (C).
Bosch Rexroth AG
Maintenance and Service
Hot connection sockets!
67/79

Advertisement

Table of Contents
loading