Technical Specifications
5.6 Operating Environment
d
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of
patches and splices. Consult a Siemens sales associates when determining maximum segment distances.
5.6

Operating Environment

The RUGGEDCOM M2100F is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
Ambient Storage Tem-
perature
Ambient Relative Hu-
midity
Maximum Altitude
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
b
Non-condensing
5.7

Mechanical Specifications

Weight
Ingress Protection
Enclosure
5.8

Dimension Drawings

Note
All dimensions are in millimeters, unless otherwise stated.
Note
Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stat-
ed.
28
-40 to 85°C (-40 to 185 °F)
a
-40 to 85°C (-40 to 185 °F)
5% to 95%
b
2000 m (6562 ft)
5.2 kg (11.5 lbs)
IP20
18 AWG Galvanized Steel
RUGGEDCOM M2100F