ENGLISH
Thank you for purchasing this SHARP Dehumidifi er.
Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.
CONTENTS
PART NAMES ..................................................................................................4
PREPARATION ................................................................................................6
START/STOP ...............................................................................................6
LAUNDRY OPERATION .............................................................................7
TIMER OPERATION ....................................................................................8
SWING LOUVER .........................................................................................9
CHILD LOCK ................................................................................................9
HOW TO DRAIN ............................................................................................. 11
TROUBLESHOOTING ....................................................................................14
SPECIFICATIONS ...........................................................................................15
Dehumidify
In accordance with the principle of generating water droplets
when warm air with much moisture gets contact with cold
items, wet air is blown in a evaporator to remove moisture.
In the following cases, the compressor will stop and will not
dehumidify.
• When the room temperature is lower than 4°C or higher than 38°C.
• The 3 minutes when the Main Unit operated again in the following
to protect the Main Unit.
* Immediately after the power plug is inserted.
* Immediately after the Laundry Drying/
Dehumidifying operation is stopped.
• When the room temperature falls below 18°C, the compressor will
stop and "HIGH" air fl ow mode will operate for about 12 minutes once every 45 minutes to prevent frost
damage inside the Main Unit. (DEFROST mode / The DEFROST Indicator Light is turned on. )
④
Dry air
③
Condenser
②
Evaporator
①
Damp air
Water Tank