Error code / Fault display / Signal

Fault
E:21-60 will light up altern-
ately.
E:30-00 will light up altern-
ately.
E:31-00 will light up altern-
ately.
E:34-00 will light up altern-
ately.
E:32-00 will light up altern-
ately or indicator for water
supply lights up.
Cause
Appliance has detected cal-
cified heating element.
Water protection system is
activated.
Water protection system is
activated.
Water is continuously run-
ning into the appliance.
Supply hose is kinked.
Water tap is turned off.
Water tap is jammed or
furred up.
The filters in the water con-
nection of the supply or
AquaStop hose are blocked.
Troubleshooting en
troubleshooting
Descale the appliance.
1.
Operate the appliance with the Wa-
2.
ter softening system.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 61.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 61.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 61.
Install the supply hose without
kinks.
Turn on the water tap.
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.
Remove the filter from the supply
5.
hose
Clean the filter.
6.
Re-insert the filter in the supply
7.
hose.
Screw the water connection back
8.
on.