When Check Character is set to Validate, but Don't Transmit, the unit will only read Codabar bar codes printed with a
check character, but will not transmit the check character with the scanned data.
* No Check Character
Validate Modulo 16, but
Don't Transmit
Validate Modulo 16
and Transmit

Codabar Concatenation

Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having
a "D" start character, adjacent to a symbol having a "D" stop character. In this case the two messages are concatenated
into one with the "D" characters omitted.
A 1 2 3 4 D
D 5 6 7 8 A
Select Require to prevent the scanner from decoding a single "D" Codabar symbol without its companion. This selection
has no effect on Codabar symbols without Stop/Start D characters.
On
* Off
Require
Codabar Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description
(page 6-1) for additional
information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60.
Minimum Message Length
6 - 3