VERIFICHE DI PRIMA INSTALLAZIONE - SOLLEVATORE TIPO RAVAGLIOLI ...
N° MATRICOLA ...
Verifica distanza del sollevatore dai muri dove è installato (non inferiore a 28" (700 mm))
Verifica tensione funi
Verifica altezza di sollevamento dal piano pavimento a piano pedane (vedi pag. 16)
Livellamento basi mettendo eventualmente spessori sotto le colonne
Serraggio tasselli fissaggio colonne
Serraggio tubi idraulici da centralina a utilizzi
Controllo livello olio centralina
Controllo allacciamento rete e collegamento cavi
Attivazione sicurezze
Collegamento impianto pneumatico
Spurgo aria impianto idraulico
Verifica comandi elettrici (l'interruttore generale, pulsante salita, pulsante discesa, pulsante di stazionamento)
Controllo inserimento arpioni su cilindri
Controllo tempi di salita e discesa a pieno carico
DATA
FIRMA INSTALLATORE
INITIAL INSTALLATION INSPECTIONS - LIFT TYPE RAVAGLIOLI...
SERIAL NUMBER...
Check distance of the lift from any walls (not less than 28" (700 mm))
Check cable tension
Check elevation height from floor to platform surface (see page 16)
Level base, place shims under post feet if needed
Check that post anchoring bolts are well tightened
Check that hydraulic lines across hydraulic unit and items are well tightened
Check oil level in hydraulic unit
Check main and cable connections
Operate safety devices
Pneumatic system connections
Bleed air for hydraulic system
Check power controls (main switch, rise button, descent button, hold button)
Check that safety catches engage properly with cylinders
Check up/down times with full load
DATE
INSTALLER SIGNATURE
98
0750-M001-0
FIRMA UTILIZZATORE
USER SIGNATURE