Ksenia Lares Series User Manual

Ksenia Lares Series User Manual

Burglar alarm systems
Hide thumbs Also See for Lares Series:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

KSI1000016.300 - KSI1100016.300 - KSI1000048.300 - KSI1100048.300 - KSI1100128.300
Manuale d'uso utente/ User manual
Centrali antintrusione serie lares™
Lares™ series Burglar Alarm Systems
1
www.kseniasecurity.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lares Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ksenia Lares Series

  • Page 1 KSI1000016.300 - KSI1100016.300 - KSI1000048.300 - KSI1100048.300 - KSI1100128.300 Manuale d'uso utente/ User manual Centrali antintrusione serie lares™ Lares™ series Burglar Alarm Systems www.kseniasecurity.com...
  • Page 2: Table Of Contents

    Le procedure per il collaudo dipendono dalla configurazione del sistema. Chiedere all’installatore del sistema le procedure da seguire. Ksenia Security srl declina ogni responsabilità nel caso in cui le apparecchiature vengano manomesse da personale non autorizzato. Il contenuto di questo manuale può...
  • Page 3: Introduzione

    INTRODUZIONE lares è una centrale antiintrusione e domotica al tempo stesso, che può essere controllata da tastiera ergo , da remoto via telefono oppure via WEB tramite il WEB server integrato. In questo manuale sono presentate le operazioni che possono essere eseguite dall'utente finale. OPERAZIONI DA TASTIERA Per l'uso delle funzionalità...
  • Page 4: Menu Principale

    differente per ciascuna tastiera. Le informazioni visualizzabili sono: Data ed ora Stato di inserimento dell'impianto Temperatura esterna (richiede almeno una sirena da esterno imago BUS) Temperatura interna (richiede almeno una sirena da interno radius BUS) Operatore GSM (richiede comunicatore gemino BUS) Zone aperte in tempo reale NOTA: nei menu utente, se non si preme alcun tasto per 30 secondi la tastiera torna automaticamente allo stato di risposo.
  • Page 5: Operazioni Con La Chiave

    Il menu di navigazione avanzato è costituito dalle seguenti voci, sulle quali è possibile muoversi utilizzando lo scroll circolare. Registro Eventi: visualizzazione del registro eventi. Premendo il tasto Enter è possibile entrare nella visualizzazione del registro eventi, e navigare tra gli eventi partendo dall'ultimo registrato. Per avere ulteriori dettagli sull'evento è...
  • Page 6: Controllo Remoto Dell'impianto Via Web

    Attivazione assistenza remota Attivazione scenari via SMS Il formato del SMS deve essere il seguente: <codice utente>s<numero di scenario> Supponiamo, ad esempio, di voler attivare lo scenario 1 (inserimento) con il PIN utente di default (147258). Bisognerà inviare alla centrale un SMS con il seguente testo: 147258s1 E’...
  • Page 7: List Of Contents

    Please ask the system installer what procedures should be followed. Ksenia Security srl waive any and all liability should the equipment be tampered with by unauthorized personnel. The contents of this manual may be subject to change without prior notice and the manual itself does not legal bind KSENIA SECURITY.
  • Page 8: Introduction

    lares ergo is a burglar alarm & Home Automation system that can be controlled by means of an keyboard, as well as remotely by telephone, and even via the Internet through a built-in WEB server. This manual describes the operations that can be performed by the end user. KEYBOARD OPERATIONS Refer to the keyboard manual to use the ergo capsense keyboard and get familiar with the functions of its keys and circular scroll...
  • Page 9: Login By User Pin

    Date and time System activation status (On or Off) Outdoor temperature (requires at least an imago BUS outdoor siren) Indoor temperature (requires at least a radius BUS indoor siren) GSM operator (requires a gemino BUS link) Real-time indication of open zones NOTE: in the user menu, if no key is pressed within 30 seconds, the keyboard will automatically return to the stand-by mode.
  • Page 10: Operations With Key

    Scheduler: in this menu it is possible to enable/disable the autoarming feature Enable Maint.: in this menu you can enable the installer to log in for system maintenance. If this option is set to OFF, the installer will have no access to the system for any operation whatsoever. Remote ass.: in this menu it is possible to enable/disable the remote assistance Phone Book: In this menu it is possible to program the phone numbers to call.
  • Page 11: Remote Control Via Web Browser

    For example let’s suppose that we want scenario number 1 (arming)to be turned on by default user PIN (147258). The SMS that should be sent to the panel will be: 147258s1 It is possible to program up to 8 different numbers that the system could send back an SMS of acknow- ledge to, after the arming is executed.
  • Page 12 lares ™ è stata progettata e realizzata con le seguenti caratteristiche per ridurne l’impatto ambientale: • Laminati per circuiti stampati senza piombo e bromo • Basso assorbimento • Imballo realizzato per la maggior parte con fibre riciclate e materiali provenienti da fonti rinnovabili we care lares ™...

Table of Contents