Ninglu SIM999 Operation Manual

Ninglu SIM999 Operation Manual

Speed log simulator and nmea0183 tester

Advertisement

Quick Links

Speed Log Simulator
and NMEA0183 Tester
SIM999
Operation Manual
Document: NLT-SIM999-SSEN
Edition:
V140825

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIM999 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ninglu SIM999

  • Page 1 Speed Log Simulator and NMEA0183 Tester SIM999 Operation Manual Document: NLT-SIM999-SSEN Edition: V140825...
  • Page 2: Table Of Contents

    Contents Introduction ................1 Features ................1 Functions ................1 Packing List ............... 3 Button Description ............3 Specifications................ 5 Summary ................5 Analog Parameters............5 Operation ................6 Charge ................6 Menu ................... 7 Language Selection ............ 8 Speed Log Simulator ..........9 Speed Log Test............
  • Page 3: Introduction

    SIM999 is a handheld portable tester for Doppler speed log,transducer and NMEA0183 (IEC61162-1). Doppler speed log tester SIM999 can measure the output of a Doppler speed log, and if required, reply with a user defined signal to simulate operation of the transducer. NMEA0183 tester SIM999 receives and displays the NMEA0183 signal.
  • Page 4 NMEA0183 tester Receive and display the NMEA0183 signals output from the connected device. Doppler speed log teaching system (optional) Optional part for speed log teaching system, please contact NINLGU if you need to this function.
  • Page 5: Packing List

    Introduction Packing List Description Comment Specification Function Simulator connect speed log 2m length data cable with this unit connect NMEA signal NMEA cable 0.5m length with this unit (110/220V) Battery charge build-in battery charger 12.6V/350mA Button Description PC RS232 interface NMEA interface LED indicators Power on/off...
  • Page 6 Introduction LED Indicators: Pulse yellow light will flash when receiving the input from speed log. Echo red light will flash when outputting bottom echo signal. Note: The echo light will not flashing until the pulse light flashing. Power on/off: Switch on/ off power. Menu Navigation Buttons: Flashing cursor key, change the location of flashing cursor Increase/decrease key, increase/decrease parameter value...
  • Page 7: Specifications

    Specifications Summary Display screen: 128×64 dot-matrix LCD Dimension: 235mm×135mm×55mm Weight(battery included): 700g Build-in rechargeable lithium battery: 12.6VDC 1500mAh Battery charger: 12.6V/350mA Working temperature: -15~55℃ Analog Parameters Parameters Range Resolution Accuracy Input Frequency 900 kHz - 2100 100 kHz ±10 kHz Input Width 9,000 us - 60,000 100 us...
  • Page 8: Operation

    Note: This manual introduces the operation of SIM999 by taking an example of Ninglu DS99 Doppler speed log, but the SIM999 is not limited to connect with the DS99 and it can also be applied to other logs within the parameter ranges on Page 4 (Analog parameters).
  • Page 9: Menu

    Operation Menu After the power-on, display the product's software version number and welcome words first, and then enter the main menu with 1-3 options. Press to change the location of the flashing cursor, press enter the option, press to change the parameters which will be saved automatically, and press to return to the previous menu.
  • Page 10: Language Selection

    Operation Language Selection After the power-on, display the product's software version number and welcome words first, and then enter the main menu. For the change language, Press before you enter the main menu, then the language selection screen will appear, press to change the location of the flashing cursor, and press to enter the selected...
  • Page 11: Speed Log Simulator

    Operation Speed Log Simulator Speed Log Test Speed log tester is used to measure the frequency, pulse width and peak to peak value of speed log. Before testing, the speed log should be connected properly and be turning on (the pulse yellow light flashing), and then enter the main menu. Press to select “1.
  • Page 12: Simulator Set

    “OutDepth” and “OutWidth” are unknown, the proposed values can be used. Parameters of Part of Speed Log Simulator Setting: Simulator Set DS99(NINGLU) JLN-205(JAPAN JRC) DS80(JAPAN Furuno) CentFreq 1000 kHz...
  • Page 13: Simulator Run

    00 kn - 10 kn StepTime 0 min - 5 min At first, the SIM999 should be connected with the Doppler speed log properly and turn on the speed log. Press to send signal and the pulse yellow light will be flashing. If parameters are set correctly, the echo red...
  • Page 14 Operation ③Confirm”2.SIMUL ATOR SET” to be ⑥To observe set correctly. whether displayed speed follow the rule of set ④Select 3, press to enter the set screen. ② Pulse yellow light flashing ⑤ Press DS993 DS992 send signal, the ① Connect speed Transceiver Controlle screen...
  • Page 15 Operation Transducer Tester In the main menu screen, press to select “2. TRANS TESTER”, to change press to enter “TRANS TEST SET”, press the cursor location and then press to set the parameters of start frequency, end frequency and step. When testing the transducer, please set the scan range near the resonance point.
  • Page 16: Nmea0183 Test

    Operation NMEA0183 Test Read the NMEA0183 sentences from the tested device. In the main menu screen, press to select “4. NMEA0183 TEST”, press to display the tested results, and press to cancel and return to the main menu. DS99 Doppler speed log DS993 Transceiver ②Select 3, press...
  • Page 17: Connection

    Connection Connection with Doppler Speed Log Use the simulator data cable (2 meters) to connect the Doppler speed log and SIM999 according to the signal instructions. Transducer's fore signal Transducer's aft signal Connection with Ninglu Doppler speed log DS99: Note: The color marked on DS993's J2 port is not associated with...
  • Page 18: Connection With Nmea0183 Interface

    Connection Connection with NMEA0183 Interface Use NMEA0183 cable (0.5 meters) to connect NMEA0183 output interface and SIM999 according to the signal instructions. Cable color Signal Cable color Signal No use Blue RXA (-) Black No use Yellow RXB (+) Refer to NMEA signal instructions of the tested device, connect NMEA A or...

Table of Contents